background image

Installation & Maintenance Instruction

CET Group Co., Ltd.

www.cetgroupco.com

39.

Do not fully insert the drum axle before reinstalling the grey handle

40.

Reinstall the grey handle

41.

Push the drum axle till it is locked with the locking tab

42.

Reinstall the spring using a small flat bit screwdriver to help guide the spring in place

43.

Remove the paper clips to release the PCR

44.

Make sure the OPC drum rotates smoothly. Wipe off any dust from the PCR with a clean, dry, lint

free cloth as it is rotated by the drum.

45.

To find the components used in this video please visit our web site www.cetgroupco.com