39.
Do not fully insert the drum axle before reinstalling the grey handle
40.
Reinstall the grey handle
41.
Push the drum axle till it is locked with the locking tab
42.
Reinstall the spring using a small flat bit screwdriver to help guide the spring in place
43.
Remove the paper clips to release the PCR
44.
Make sure the OPC drum rotates smoothly. Wipe off any dust from the PCR with a clean, dry, lint
free cloth as it is rotated by the drum.