SmaRT Console Box Remote
U093.3.0
16
3.0
Umbilical Connection (Option)
The umbilical connector is located on the right side of the console box. The connector is capped
to protect it when it is not being used. The standard connector is a four-pin connector that allows
for hardline CAN communications. When the CAN option is active, the console box radio is
disabled, and all commands are issued to the base unit through the umbilical cable. Cervis, Inc.
offers an array of umbilical kits that simplify connecting a SmaRT console box. Figure 8
illustrates an example of a C4-20 Umbilical Kit that may be used in a SmaRT console box
system.
Figure 8. Umbilical Connection Option and C4-20 Umbilical Kit Example
Umbilical Power: 7 V
– 32 V
Base unit connections are determined
by the specific base unit used in the
SmaRT system. These connections
are detailed in the Engineered System
Manual (ESM) or Engineered System
Documents (ESD) shipped from
Cervis, Inc. with the system.