Rev G
Page 5
5/9/2017
Copyright © 2017 by Certified Cirus Control Systems. All Rights Reserved. No part of this material may
be reproduced in any form without the express written permission of Certified Cirus Control Systems
Feature Overview
SCMC
TM
Control Panel Front View
Power Switch:
Main system power switch.
Engage:
Enables the
SCMC
TM
to take control of the contact weight.
Set Point:
Dial used to set the contact weight of the implement.
Red LED:
Voltage output signal on or off.
SCMC
TM
Control Panel Back View
POWER
: Provides power and ground to unit. (MK-1003 cable)
PWM
: Voltage signal output to the valve controlled by the set point. (SF-1005 cable)
VALVE POWER
: On/Off output signal to the valve. (MK-2005 cable)
TRIG:
Enables the
SCMC
TM
to take control of contact weight. (JP-1002 cable)