7
Pressure loss table
(T3.3)
Valve operating torque
Operating torque values at rated pressure (PN) and 20 °C as supplied by default from the factory. Installation and operating conditions
(pressure and temperature) may affect these values.
The actuator required for an automatic operation must be calculated according to some safety factors that were determined in tests
carried out in the factory.
DN15
DN20
DN25
DN32
DN40
DN50
DN65
DN80
DN100
N·m
1
2
3,5
3,5
5
15
25
45
lbf·inch
8,9
17,7
31
31
44,3
132,8
221,3
398,3
(T3.2)
Operating torque table (N·m)
4.
DIMENSIONS
T 4.1(mm)
DN
D / G
L
H
E
F
15
16 - 3/8”
13
87
50
64
15
20 - 1/2”
16
87
50
64
20
25 - 3/4”
19
101
61
64
25
32 - 1”
22
122
70
74
32
40 - 1 1/4”
26
135
81
74
40
50 - 1 1/2”
31
149
96
88
50
63 - 2”
38
174
118
88
65
75 - 2 1/2”
44
216
146
123
80
90 - 3”
51
256
176
123
100
110 - 4”
63
359
225
165
See the actuator manual to check the dimensions M and N.
Check the technical catalog for the rest of dimensions for flange con-
nections, PE-100, PPH butt welding PPH and the rest of end connectors.
DN
ISO FLANGE
SQUARE OPTIONS (mm)
15
F03-F04-F05
9/11/14
20
F03-F04-F05
9/11/14
25
F05
11/14
32
F05
11/14
40
F05-F07
11/14/17
50
F05-F07
11/14/17
65
F07
17
80
F07
17 / 22
Fig. 5
Fig. 4
DN
D
Kv (l/min)
Cv (GPM)
10
16
75
5,3
15
20
190
13,3
20
25
380
26,6
25
32
690
48,3
32
40
980
68,6
40
50
1600
112
50
63
3000
210,1
65
75
5500
385,2
80
90
6800
476,2
Actuator coupling dimensions
(T4.2)
H
L
F
E
M
N
Valve design
Valve connections
Actuator coupling
EN ISO 16135:2007
Threads: ISO 7-1, ISO 228-1
Flanges: EN 558-1, EN 1092-1
PVC-U, CPVC
: ISO 15493
PPH, PE-100
: ISO 15494
EN/ISO 5211
ENGLISH
[IND] ELECTRIC BALL VALVE
Summary of Contents for PPH