![Cepex PPH Installation And Maintenance Manual Download Page 11](http://html1.mh-extra.com/html/cepex/pph/pph_installation-and-maintenance-manual_2583341011.webp)
11
9.
SPARE PARTS
DN
VALVE
KIT
JJ ACT.
KIT
VALPES ACT.
SEE TECHNICAL
CATALOG TO
KNOW THE
SPECIFIC CODE
12-48V
80-240V
100-240V
15-30V
DN15 (
⅜
”)
53944
30671
30676
43676
30682
30692
DN15 (½”)
43944
30671
30676
43676
30682
30692
DN20 (¾”)
43945
30671
30676
43677
30682
30692
DN25 (1”)
43946
30671
30676
43678
30682
30692
DN32 (1¼”)
43947
30671
30676
43679
30682
30692
DN40 (1½”)
43680
46651
46652
43680
30682
30692
DN50 (2”)
43681
46651
46652
43681
30682
30692
DN65 (2½”)
43682
30672
30677
46667
30683
30693
DN80 (3”)
43683
46653
46654
46668
30683
30693
DN100 (4”)
30579
30673
30678
30589
30684
30694
10.
TROUBLESHOOTING
T 9.1
FAULT
POSSIBLE CAUSE
FAULT CLEARANCE
Leak in the valve body.
Wear of the body o’ring.
Change the o’ring.
Loosening of the seal carrier.
Adjust the seal carrier.
Presence of solids or strange elements.
Remove the valve and replace damaged parts.
Leak in the valve shaft.
Wear of the shaft o’rings.
Change the o’rings.
The torque is too strong or the
valve is blocked.
The seal carrier is over-tight
Adjust the seal carrier.
The valve does not open or
close.
Lack of current.
Check current supply to the actuator
The valve does not close
completely.
The actuator stroke is not properly adjusted to the
valve.
Check adjustment limits according to the actuator manual.
The torque of the valve has increased above the
calculated value.
Check the valve: obstructions in the disc or malfunction
of the valve.