Installation Preparation

Installing the MP412 is easy as long as you do a little planning before starting. Locate the unit  within ten feet of an a. c. power outlet and seven feet of
the telephone jacks. The maximum amount of telephone wire that can be between the unit any station is 600 feet. The MP412 has been assigned the
station number 22. Any NSQ412 that uses this station number will have to be changed to another number.

IMPORTANT:

Taking full advantage of the system features requires that the telephone number connected to Line 1 be the same on all stations. If this

is not done, the Page will not work properly. In addition, it is strongly recommended that no other devices operate on Line 1 or Line 2 besides the
NSQ412 stations and the MP412. Any interference on it can degrade the system performance. The system can be used on a DLS line if either: 1) 
Line 1 is not the DSL line; or 2) Line 1 wiring connected to all stations is behind the DSL filter port.

CAUTION!

1. Never install telephone jacks during a lightning storm.
2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
3. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
4. Use caution when installing or modifying telephone lines.
5. Always disconnect all telephone lines from the wall outlet before servicing or disassembling this equipment.
6. Danger of explosion if battery is incorrectly replaced.

Installing the Unit on a Desk or Table

NOTE:

Do not connect the a. c. power adapter until instructed to do so.

The following instructions show how to connect four telephone lines to the MP412. As few as one line can be connected.

1. Carefully remove all of the unit components from their packing.
2. If telephone lines 1 and 2 are on one jack and telephone lines 3 and 4 are on another jack, see the following connection drawing. Otherwise, go to 

step 3.

Connect telephone jack 1 to the MP412 L1/L2 jack using one of the 4-conductor telephone line cords supplied with the unit. Connect telephone 
jack 2 to the MP412 L3/L4 jack using the other 4-conductor telephone line cord supplied with the unit.

5

GETTING STARTED

Key and Indicator Descriptions

The following drawings provide identification and brief descriptions of the control and indicator.

Power & Paging LED: Illuminates continuously for power, flashes to indicate paging or another NSQ412 has the same extension number.

Audio Out Jack: Used to provide the MP412 page signal to an external paging amplifier and speaker.

Audio In Jack: Used to connect an external music source for music on hold.

Line Jacks: Jack L1/L2 is used for telephone lines 1 and 2. Jack L3/L4 is used for telephone lines 3 and 4

Paging Volume Knob: Adjusts the paging level.

Power Jack: The jack for connecting the a. c. power adapter to the unit.

4

INTRODUCTION

MP412 Manual_rev.qxd  6/15/05  12:23 PM  Page 6

Summary of Contents for MP412

Page 1: ...4 Line Music on Hold and Paging Adapter Model MP412 OWNER S MANUAL MP412 Manual_rev qxd 6 15 05 12 23 PM Page 1 ...

Page 2: ... you should contact your local telephone company to determine the maximum REN for your calling area If your equipment causes harm to the telephone network the telephone company may discontinue your service temporarily If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be informed of your right to file a complaint with...

Page 3: ...n a fire They may explode Check with local codes for possible special disposal instructions 7 Do not allow anything to rest on the power cord Do not locate this product where the cord will be abused by persons walking on it 8 Do not overload wall outlets and extension cords as this can result in the risk of fire or electrical shock 9 Never push objects of any kind into the product through cabinet ...

Page 4: ...hone lines from the wall outlet before servicing or disassembling this equipment 6 Danger of explosion if battery is incorrectly replaced Installing the Unit on a Desk or Table NOTE Do not connect the a c power adapter until instructed to do so The following instructions show how to connect four telephone lines to the MP412 As few as one line can be connected 1 Carefully remove all of the unit com...

Page 5: ...nitialize for about 7 seconds then be ready for use 7 GETTING STARTED 3 If telephone lines 1 2 3 and 4 are all on separate jacks two adapters and extra telephone line cords are necessary not included with the unit See the following connection drawing The adapters will convert two separate telephone jacks into a single one Connect telephone line 1 into the adapter Connect telephone line 2 into the ...

Page 6: ...quency energy and if not connected and operated in accordance with the Owner s Manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of the FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation o...

Page 7: ... if an NSQ412 has a station ID of 22 If so it must be changed EXTERNAL PAGING IS NOT HEARD Turn up the MP412 Paging Volume 10 Basic Features PLACE THIS TEMPLATE ON THE WALL THE LOCATION OF THE SCREWS IS INDICATED BY THE CENTERS OF THE CROSSED LINES FASTEN THE SCREWS LEAVING 3 16 OF THE SCREW EXTENDING FROM THE WALL REMOVE THIS PAGE MP412 Manual_rev qxd 6 15 05 12 23 PM Page 12 ...

Page 8: ...ich it was purchased If is used in a country in which it is not registered for use and or if it is used in a country for which it was not designed Due to variations in telephone systems and communications laws this product may be illegal for use in some countries International Resources Inc assumes no responsibility for damages or penalties incurred resulting from the use of this product in a mann...

Reviews: