Page 28
Installation and Operation Manual - FW3500
ENGLISH
8.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
11" (279 mm)
11" (279 mm)
D
15 ¾" (400 mm)
15 ¾" (400 mm)
B
22" (559 mm)
22" (559 mm)
E
32
⅞
" (835 mm)
32
⅞
" (835 mm)
C
14" (356 mm)
14" (356 mm)
F
24 ¾" (629 mm)
24 ¾" (629 mm)
L
72" (1,830 mm)
72" (1,830 mm)
8.1.3 With Heat Shield AC02710 or AC02762 and Lowered Ceiling
16
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
16
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
2 ½" (64 mm)
2 ½" (64 mm)
D
7 ¼" (184 mm)
7 ¼" (184 mm)
B
2 ½" (64 mm)
2 ½" (64 mm)
E
13
⅜
" (340 mm)
13
⅜
" (340 mm)
C
2 ½" (64 mm)
2 ½" (64 mm)
F
13 ¼" (337 mm)
13 ¼" (337 mm)
L
74" (1,880 mm)
74" (1,880 mm)
8.1.4 Inside an Alcove
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
16
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
11" (279 mm)
11" (279 mm)
D
15 ¾" (400 mm)
15 ¾" (400 mm)
B
25" (635 mm)
25" (635 mm)
E
35
⅞
" (911 mm)
35
⅞
" (911 mm)
K
48" (1220 mm)
36" (910 mm)
L
74" (1,880 mm)
74" (1,880 mm)
15
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.
16
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.