Page 27
Installation and Operation Manual - FW3500
ENGLISH
8.1 Clearances
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
13 ¾" (349 mm)
13 ¾" (349 mm)
A
8" (203 mm)
8" (203 mm)
B
22" (559 mm)
22" (559 mm)
B
19" (483 mm)
19" (483 mm)
C
12" (305 mm)
12" (305 mm)
C
12" (305 mm)
12" (305 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
13
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18 ½" (470 mm)
18 ½" (470 mm)
D
12 ¾" (324 mm)
12 ¾" (324 mm)
E
32
⅞
" (835 mm)
32
⅞
" (835 mm)
E
29
⅞
" (759 mm)
29
⅞
" (759 mm)
F
22 ¾" (578 mm)
22 ¾" (578 mm)
F
22 ¾" (578 mm)
22 ¾" (578 mm)
8.1.1 With Heat Shield AC02710 or AC02762
14
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES13 FROM DOUBLE WALL PIPE
CONNECTOR
Canada
USA
Canada
USA
A
2 ½" (64 mm)
2 ½" (64 mm)
D
7 ¼" (184 mm)
7 ¼" (184 mm)
B
2 ½" (64 mm)
2 ½" (64 mm)
E
13
⅜
" (340 mm)
13
⅜
" (340 mm)
C
2 ½" (64 mm)
2 ½" (64 mm)
F
13 ¼" (337 mm)
13 ¼" (337 mm)
13
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.
14
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.