Century 400 1.007-905.0 Operating Instructions Manual Download Page 14

14

Operations

Operating Dehumidifier

Never allow anything to block intake airflow. Be 
careful of objects which could be drawn against 
intake. The dehumidifier must sit on a level surface. 
Always position and orient machine before turning 
on.

Ne permettez jamais à quoi que ce soit de bloquer 
l'entrée d'air. Faites attention aux objets qui pour-
raient être attirés contre l'entrée d'air. Le déhumidi-
fier  doit reposer sur une surface de niveau. Dirigez 
et orientez toujours le déhumidifier avant de 
l'allumer. 

For best results, operate dehumidifier in enclosed 
space. Close all exterior doors and windows. Keep 
traffic through drying area to a minimum

1.

Connect drain hose to condensate pump’s quick 

connect fitting. 

2.

Uncoil and straighten entire hose; to prevent water 

backing up to pump and leaking. 

3.

Place other end in a sink drain bucket or outside, 

no more than 10 ft above pump. 

NOTE: If a bucket or other receptacle is used for 
water collection, check and empty regularly to 
prevent spills.

4.

Plug in electrical cord into 115 volt GFCI protected 

outlet rated for minimum 15 amps.

5.

Turn the machine on.

Purging Dehumidifier

1.

After space reaches desired humidity level, press 

the drain button. This manually empties water from 

the condensate pump reservoir. 

2.

Disconnect drain hose.

The drain hose will be full of water. Take precautions to 
avoid spilling in undesirable areas.

!

ATTENTION:

86356330 Crusader Dehumidifier

Summary of Contents for 1.007-905.0

Page 1: ...Read these instructions before using the machine 86356330 B 11 22 11 Operating instructions ENG MODELS Crusader 75 1 007 905 0 Crusader 95 1 007 906 0 LGR DEHUMIDIFIER ...

Page 2: ...ion janitorial sanitation or other professionals needing to control humidity in an area Warranty Registration Thank you for purchasing a C400 product Warranty registration is quick and easy Your registration will allow us to serve you better over the lifetime of the product To register your product go to www century400 com support warranty register php For customer assistance 1 800 776 2436 ...

Page 3: ...tructions 9 Technical Specifications 10 Operations Components 11 Controls 12 Machine Function 13 Malfunction Indicators 13 How to Transport Dehumidifier 13 Cord Storage 13 Storing in Warehouse and in Delivery Truck 13 Operating Dehumidifier 14 Purging Dehumidifier 14 Service Schedule 15 Cleaning Dehumidifier 15 Replace Condensate Pump 16 Fan Replacement 16 Thermistor Replacement 16 Troubleshooting...

Page 4: ...s general order Storage Maintenance Troubleshooting The PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of information REF column refers to the reference number on the parts illustration PART NO column lists the part number for the part PRV NO reference number QTY column lists the quantity of the part used in that a...

Page 5: ...airs must be done by qualified personnel The machine shall only be operated by instructed and authorized persons Do not handle the plug or machine with wet hands Do not unplug machine by pulling on cord To unplug grasp the plug not the cord Do not use with damaged cord or plug Do not pull or carry by cord use cord as a handle run over cord close a door on cord or pull cord around sharp edges or co...

Page 6: ...e l appareil est exclusivement réservé à des personnes formées et autorisées Ne manipulez pas la fiche ou l appareil les mains mouillées Ne débranchez pas l appareil en tirant sur le cordon Pour le débrancher empoignez la fiche non pas le cordon N utilisez pas l appareil si le cordon ou la fiche est endommagé e Observez toutes les consignes figurant dans ce manuel au sujet de la mise à la terre de...

Page 7: ...t machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentially dangerous conditions to the operator or the equip ment Read this information carefully Know when these conditions can exist Locate all safety devices on the machine Please take the necessary steps to train the machine operating pe...

Page 8: ...étérioration de la machine Ne pas utiliser la machine si celle ci ne fonctionne pas correctement Lire soigneusement les informations ci dessous signalant certains dangers potentiels pour l opérateur de la machine L opérateur doit être absolument au courant de ces dangers potentiels Localiser tous les dispositifs de sécurité sur la machine Il est conseillé de prendre les mesures nécessaires pour fo...

Page 9: ... used only until a properly grounded outlet Fig A can be installed by a qualified electrician The green colored rigid ear lug or the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adaptor is used it must be held in place by a metal screw Improper connection of the equipment grounding conductor can result in a risk o...

Page 10: ...o be 60 dB A This was a nearfield broadband measure ment taken in a typical industrial environment on a tile floor ITEM MEASURE Height 37 7 In 96 cm Length 24 In 61 cm Width 22 8 In 58 cm Weight Crusader 75 119 Lbs 54 kg Crusader 95 126 Lbs 57 kg Cord 25 X 14 Gauge 3 Wire Black Body Construction Rotationally Molded Polyethylene Frame Construction Powder Coated Steel Refrigerant R410A Water extract...

Page 11: ...rations Components 1 2 3 4 5 6 7 8 9 10 1 FILTER COVER 2 FILTER 3 UPPER HOUSING 4 LOWER HOUSING 5 WHEELS 6 CORD STORAGE 7 CONTROL PANEL 8 HANDLE 9 EXHAUST OUTLET 10 WATER OUTLET 86356330 Crusader Dehumidifier ...

Page 12: ...the humidity 1 When the Humidity Up button is pressed for 2 seconds humidity is raised by 5 per second 9 Humidity Down When machine runs on dehumidify mode each time the Humidity Down button is pressed it lowers the humidity 1 When the Humidity Down button is pressed for 2 seconds humidity is lowered by 5 per second 10 Drain press Drain button to empty water in pump automatically 86356330 Crusader...

Page 13: ...ns off When the water tank is full the pump starts to discharge the water If the pump stops E4 will be displayed Machine run time on display shows how much time the machine has operated This number is calculated every ten minutes and the first ten minutes after the machine is started are not calculated Malfunction Indicators If the machine detects a fault the following codes will be displayed How ...

Page 14: ... traffic through drying area to a minimum 1 Connect drain hose to condensate pump s quick connect fitting 2 Uncoil and straighten entire hose to prevent water backing up to pump and leaking 3 Place other end in a sink drain bucket or outside no more than 10 ft above pump NOTE If a bucket or other receptacle is used for water collection check and empty regularly to prevent spills 4 Plug in electric...

Page 15: ...o ease lifting the upper housing Lift the upper housing up and forward the sides of the housing must be flared out to prevent interfer ance with the cassette 5 Remove the condensate hose from the hosebarb on the inside of the upper housing 6 Disconnect the control panel wires from the display board 7 Remove the lower back screws and lower side screws To access the screws behind the wheels remove t...

Page 16: ...er screws on the back of the machine 4 Remove the filter to ease lifting the upper housing Lift the upper housing up and forward the sides of the housing must be flared out to prevent interfer ance with the cassette 5 Remove the condensate hose from the hosebarb on the inside of the upper housing 6 Disconnect the control panel wires from the display board 7 Remove the lower back screws and lower s...

Page 17: ...it Find and repair bad connection Obstruction blocking impeller motion Remove blockage Machine doesn t extract as much water as expected Air Temperature Humidity has dropped Retest Temperature Humidity Recalculate Machine has entered defrost cycle Wait 1 hour recheck Dirty air filter Clean Replace filter Frosted coils Check Replace thermister or control board Dirty coils Clean coils Low refrigeran...

Page 18: ...18 86356330 Crusader Dehumidifier Notes ...

Page 19: ...19 PARTS 86356330 Crusader Dehumidifier Parts ...

Page 20: ...20 Parts List 1 2 3 4 5B 6B 7 8 9B 10 11 12B 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 36 35 5A 6A 9A 12A 86356330 Crusader Dehumidifier ...

Page 21: ...520 HEAT EXCHANGER 11 86356530 FILTER 12A 86356540 CONDENSER 75 pint CRUSADER 75 ONLY 12B 86356550 CONDENSER 95 pint CRUSADER 95 ONLY 13 86356560 AIR DUCT BOARD 14 86356570 BLADE 15 86356580 VOLUTE CASING 16 86356590 MOTOR 17 86356600 FILTER COVER 18 86356610 UPPER HOUSING 19 86356620 TEMPERATURE SENSOR 20 86356630 ELECTRICAL MOUNTING BOARD 21 86356640 CAPACITOR CLAMP 22 86356650 WIRE CONNECTION S...

Reviews: