page 14
www.CentSys.com
S
ECTION
3
S
PECIFICA
TIONS
Wind speeds for which operator will still operate the gate.
(
VANTAGE 400
or
VANTAGE 500
operators)
For a 25% covered gate: (Palisades, etc.) x 1.8 metre high
Value of
A or B
dimension
once
installed
1
Individual gate leaf lengths:
Up to
1.5m
Up to
2m
Up to
2.5m
Up to
3m
2
Up to
3.5m
2
Up to
4m
2
100mm
94km/h
66km/h
48km/h
44km/h
41km/h
37km/h
140mm
119km/h
85km/h
65km/h
57km/h
51km/h
46km/h
180mm
138km/h
101km/h
78km/h
67km/h
60km/h
53km/h
220mm
156km/h
114km/h
89km/h
76km/h
67km/h
60km/h
260mm
171km/h
126km/h
99km/h
84km/h
74km/h
65km/h
300mm
186km/h
137km/h
108km/h
91km/h
80km/h
71km/h
340mm
199km/h
147km/h
116km/h
98km/h
86km/h
76km/h
Wind speeds for which operator will still operate the gate.
(
VANTAGE 400
or
VANTAGE 500
operators)
For a 100% covered gate: (Fully-clad gates, etc.) x 1.8 metre high
Value of
A or B
dimension
once
installed
1
Individual gate leaf lengths:
Up to
1.5m
Up to
2m
Up to
2.5m
Up to
3m
2
Up to
3.5m
2
Up to
4m
2
100mm
47km/h
33km/h
24km/h
22km/h
47km/h
19km/h
140mm
59km/h
43km/h
32km/h
28km/h
59km/h
23km/h
180mm
69km/h
50km/h
39km/h
34km/h
69km/h
27km/h
220mm
78km/h
57km/h
44km/h
38km/h
78km/h
30km/h
260mm
86km/h
63km/h
49km/h
42km/h
86km/h
33km/h
300mm
93km/h
63km/h
54km/h
46km/h
93km/h
35km/h
340mm
100km/h
74km/h
58km/h
49km/h
100km/h
38km/h
TABLE 6
TABLE 7
1. See Section 9/10 for installation details
2. An electric lock must be fitted
1. See Section 9/10 for installation details
2. An electric lock must be fitted
3.7. Allowable Wind Load