Troubleshooting
13-3
Ramfill Valve and Clip
Figure 13-1
The ramfill valves are not
opening
• Are you up to 10 MPH to operate
Ramfill? Are you over 25 MPH?
• If all the valves are not working then the
problem is most likely associated with the
PDM. Check to make sure that all the
electrical plug in’s that go to the PDM are
secure.
• Check the Pinouts on the wires that go to
the PDM to see if they are dislodged.
When connected, each contact of a
Pinout connector must mate with the
contact on the other connector that has
the same function.
• If the problem continues you will need to
contact your local service center to
determine whether the PDM needs to be
replaced.
Problem
Possible Causes