page 23
www.centsys.com
LED FLASHES
LATCHING
PANIC
*
OFF
OFF
**
ON
OFF
***
OFF
ON
****
ON
ON
TABLE 10. CHANNEL CONFIGURATION
TABLE 11. OUTPUT PULSE TIME SETTINGS
6.
Once the output configuration has been set, it is possible to proceed to set the output
pulse time. This step may be skipped by either waiting 5 seconds for the receiver
to time out, or by removing power from the board. In either of the two cases, the
currently set output pulse time will be maintained.
7.
To adjust the relay output pulse time, fit the link across jumper J2 again. Ensure that
this is done before the 5 second timeout period elapses.
8.
Once the link is fitted, the LED will illuminate for 3 seconds. If the link is removed
within this three second window, the relay time is set to the minimum pulse time of
0.3s. In such a case, skip the next step and proceed to step 10.
9.
After the three second window, the LED will switch off and start flashing once per
second. Counting LED flashes, or using a watch to keep track of the number of
seconds that pass will determine the period of the output pulse time. When the
desired time period is reached, the link on J2 must be removed.
10. If the link across jumper J2 is not removed after a period of 240 seconds, the LED
will stay on permanently. If the jumper is removed after this, the receiver will set the
maximum pulse time-period of 240s.
11.
The buzzer will beep briefly when the link is removed to confirm that the new time
has been saved.
12.
The receiver will now exit channel configuration mode, transitioning to normal mode
of operation. If additional receiver outputs must be configured, the above steps must
be repeated for the relevant output.
Number of LED Flashes When J2 Link
is Removed
Relay Output Pulse Time
Initial 3 Second Window
0.3s
1 flash
1.0s
2 flashes
2.0s
3 flashes
3.0s
...
...
240 flashes
4 minutes
S
ECTION
5
OUTPUTS