Centrometal CentroPelet ZV14 Technical Instructions Download Page 9

Smokes exhaust safety

A mechanical depressor checks the correct depression for 
a proper smokes exhaust. On the contrary, if the flue is ob-
structed,  the  pellet  boiler  stove  switches  off  and  you  will 
read the words 

‹#J?P&CN(?GJŒ

 on the display.

Pellets temperature safety

In the rare event there is a too high temperature in the tank, 
the thermostat for pellets safety with manual reset creates 
an alarm 

#J?P5GA(?GJ

 stopping the pellet boiler stove. You

need to reset the system working on the device placed on 
the back of the stove (Pict. 5)

Water temperature safety

In the event the water temperature exceeds a limit value of 
100°C, the thermostat for water safety lets the stove switch 
off. You will read the words 

‹#J?P5GA(?GJŒ

on the display. Once

you have waited a minimal time required for water cooling, 
you need to reset the thermostat placed on the back of the 
stove (fig. 5).

Manual reset thermostat

System pressure safety

The system pressure is checked electronically and needs to 
be between 0,5 and 2,3 bar. If this is not the case, the pellet 
boiler stove signalises an alarm and shows the words “Alar 
Press” on the display. Check the system pressure keeping 
the key    

   

      pressed for some seconds. You will read the 

bar value on the display.
The safety valve keeps anyway the value under 2,5 bar let-
ting the exceeding water flow out automatically.

Failed light-up

If the flame does not light up during the switching on or if 
the smokes temperature does not reach a suitable value in 
the foreseen time gap, the stove switches off and you will 
read the words

‹#J?P0M#AAŒ

 on the display.

฀ ฀

cooling  phase  is  completed,  clean  the  brazier  and  start  a 
new light-up.

Switching off while working

The stove suddenly switches off while working (for example 
because  it  has  run  out  of  pellets  in  the  tank  or  because 
the motor reducer for pellets loading got broken). The stove 
continues working until the pellets left in the brazier ends. 
You will then read the words

‹#J?P0M(GPCŒ

 on the display and 

฀ ฀

alarm. Wait until the cooling phase is completed. Clean the 
brazier and start a new light-up.

These alarms remind you that the brazier must be cle-
aned  and  installed  correctly  before  switching  on  the 
stove.

There is no power supply

In  the  event  of  a  power  drop  longer  than  one  minute,  the 
pellet  boiler  stove  can  exhaust  some  smoke  in  the  room: 
this causes no risks.
As soon as you have the power supply again, the pellet boi-
ler stove will have the words 

‹%MMJ(GPCŒ

 on the display. After

completing the cooling phase, the stove will start up again 
automatically according to the previous settings.

Electrical safety

In the event of an electrical shock (lightning), the pellet boi-
ler stove is protected by a fuse 2,5 A 250V which is placed 
on the back of the stove near the cable for power supply. 
Extract its box and replace the fuse.

pellet

water

Pict. 5

Failure on electrical devices

CAUTION!

do not attempt to start the pellet boiler stove before the 
required time or it may get blocked.
If  this  occurs,  switch  off  the  switch  on  the  back  of  the 
pellet boiler stove for 1 minute, set it on again and wait 
10 minutes before starting the stove again.

CAUTION!

the power socket where the pellet boiler stove is con-
nected  should  be  fitted  with  “earth  connection  com-
plying  with  regulations  in  force.”  The  Manufacturer 
shall not be held responsible for damage to things or 
people resulting from negligent installation.

Summary of Contents for CentroPelet ZV14

Page 1: ...NG TECHNIQUE CentroPelet ZV14 TUZS 4 2014 ENG Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 TECHNICAL INSTRUCTIONS for regulation use and maintenance of pellet stove ...

Page 2: ...use and maintenance manual is an integral part of the product Before using installing or servicing the product read the indications contained in this manual carefully This pellet boiler stove should only be used for the intended use it has been designed for Therefore the user shall be responsible for any damage to people animals or things resulting from misuse of the product Installation should be...

Page 3: ...prox Kg 130 80 mm 50 mm 3 4 220V 50Hz 90 W 350 W only start phase 17 kg Weight Flue pipe diameter Air intake pipe diameter Power Supply Min electrical input Max electrical input Hopper capacity Pict 1 Aproximative dimensions mm ...

Page 4: ...e upper display and the system delivery water temperature will be shown on the lower display If the flame does not start up correctly within 10 minutes the pellet boiler stove jams you will read the words 4 on the upper display and the words 01 blinking on the lower di splay Wait 10 minutes until the cooling phase is completed open the door empty the brazier and start a new light up Pict 2 Prelimi...

Page 5: ...the water temperature on the lower display REMARKS The pellet boiler stove is fitted with an automatic device that allows clea ning the brazier after a given period of time when this time is detected the stove fire automatically reduces and 27 4 is shown on the display After some minutes the pellet boiler stove will start working regularly Room temperature range 7 C 40 C WARNING Do not unplug the ...

Page 6: ...ivation The meaning of the user parameters are explained in detail below UT01 Heating timer thermostat enabling and disabling and current hour setting This parameter is used to set the current day of the week or to deactivate the set programming Press buttons and to select the desired value as shown in the following table Upper Display MEANING Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 OFF Example ...

Page 7: ...ay MEANING Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 Lower display In the following example the pellet boiler stove is only star ted on Saturdays and Sundays off 1 off 2 off 3 off 4 off 5 on 6 on 7 Confirm and continue with key If the stove is controlled by an external thermostat when the thermostat reaches the preset temperature 1 6 4 will be shown on the pellet boiler stove display CAUTION the r...

Page 8: ...20 The water temperature exceeds 90 C The cir culating pump is blocked or there is no water in the hydraulic system Check the power supply on the pump Check limestone does not block the pump impeller ALAR SOND H20 The water sensor is not connected There is a short circuit on the water sensor Check the water sensor is connected Contact an authorised qua lified technical assistance ALAR HOT TEMP The...

Page 9: ...se is completed clean the brazier and start a new light up Switching off while working The stove suddenly switches off while working for example because it has run out of pellets in the tank or because the motor reducer for pellets loading got broken The stove continues working until the pellets left in the brazier ends You will then read the words J P 0M GPC on the display and alarm Wait until th...

Page 10: ...uster to avoid ash to discharge To activate this function press the key and then the key you will read the words PUL STUF cleaning of the stove on the display In order to stop the fan you just need to press the key for a longer time waiting that a cleaning phase is completed 255 seconds EVERY DAY remove and clean the brazier Pict 6 FROM TIME TO TIME clean the exchanger every two days When the stov...

Page 11: ...Notes ...

Page 12: ...l figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot In any case it reserves the right to modify its products as deemed to be required and useful without any prior notification HEATING TECHNIQUE Centrometal d o o Glavna 12 40306 Macinec Croatia central tel 040 372 600 fax 040 372 611 service tel 040 372 622 fax 040 372 621 Notes ...

Reviews: