Centrometal CentroPelet ZV14 Technical Instructions Download Page 7

UT05
Pellet boiler stove first start-up time adjustment

This parameter indicates the time at which the pellet boiler 
stove will be started: use buttons         and          to set the 
desired time, with 10-minute steps.
Press button        to go to the following parameter.

UT06
Pellet boiler stove shutdown time adjustment

This parameter indicates the time at which the pellet boiler 
stove will be turned off: use buttons        and         to set the 
desired time, with 10-minute steps.
Press button         to go to the following parameter.

UT07
Week day selection

Press button 

 to select the days of the week. Press 

button 

 to enable (ON) or disable (OFF) the pellet boiler 

stove start-up day as shown in the following table:

Upper 

display

MEANING

Day 1

Day 2

Day 3

Day 4

Day 5

Day 6

Day 7

Lower 

display

In the following example, the pellet boiler stove is only star-
ted on Saturdays and Sundays.

off 1

off 2

off 3

off 4

off 5

on 6

on 7

Confirm and continue with key        .

If  the  stove  is  controlled  by  an  external  thermostat,  when 
the  thermostat  reaches  the  preset  temperature, 

‹'%16'4/Œ

will be shown on the pellet boiler stove display.

CAUTION!

the room temperature thermostat does not turn off and on 
the pellet boiler stove; it sets the stove in saving mode

.

UT08     UT16

 

continue  as  indicated  above  to  set  the  second,  third  and 
fourth ignition times.

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

ON1/OFF1-Yes or No

ON2/OFF2-Yes or No

ON3/OFF3-Yes or No

ON4/OFF4-Yes or No

ON5/OFF5-Yes or No

ON6/OFF6-Yes or No

ON7/OFF7-Yes or No

Day 1 

Monday

Day 2 

Tuesday

Day 3 

Wednes.

Day 2 

Thurs.

Day 2 

Friday

Day 2 

Saturday

Day 2 

Sunday

Summary of Contents for CentroPelet ZV14

Page 1: ...NG TECHNIQUE CentroPelet ZV14 TUZS 4 2014 ENG Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 TECHNICAL INSTRUCTIONS for regulation use and maintenance of pellet stove ...

Page 2: ...use and maintenance manual is an integral part of the product Before using installing or servicing the product read the indications contained in this manual carefully This pellet boiler stove should only be used for the intended use it has been designed for Therefore the user shall be responsible for any damage to people animals or things resulting from misuse of the product Installation should be...

Page 3: ...prox Kg 130 80 mm 50 mm 3 4 220V 50Hz 90 W 350 W only start phase 17 kg Weight Flue pipe diameter Air intake pipe diameter Power Supply Min electrical input Max electrical input Hopper capacity Pict 1 Aproximative dimensions mm ...

Page 4: ...e upper display and the system delivery water temperature will be shown on the lower display If the flame does not start up correctly within 10 minutes the pellet boiler stove jams you will read the words 4 on the upper display and the words 01 blinking on the lower di splay Wait 10 minutes until the cooling phase is completed open the door empty the brazier and start a new light up Pict 2 Prelimi...

Page 5: ...the water temperature on the lower display REMARKS The pellet boiler stove is fitted with an automatic device that allows clea ning the brazier after a given period of time when this time is detected the stove fire automatically reduces and 27 4 is shown on the display After some minutes the pellet boiler stove will start working regularly Room temperature range 7 C 40 C WARNING Do not unplug the ...

Page 6: ...ivation The meaning of the user parameters are explained in detail below UT01 Heating timer thermostat enabling and disabling and current hour setting This parameter is used to set the current day of the week or to deactivate the set programming Press buttons and to select the desired value as shown in the following table Upper Display MEANING Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 OFF Example ...

Page 7: ...ay MEANING Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 Lower display In the following example the pellet boiler stove is only star ted on Saturdays and Sundays off 1 off 2 off 3 off 4 off 5 on 6 on 7 Confirm and continue with key If the stove is controlled by an external thermostat when the thermostat reaches the preset temperature 1 6 4 will be shown on the pellet boiler stove display CAUTION the r...

Page 8: ...20 The water temperature exceeds 90 C The cir culating pump is blocked or there is no water in the hydraulic system Check the power supply on the pump Check limestone does not block the pump impeller ALAR SOND H20 The water sensor is not connected There is a short circuit on the water sensor Check the water sensor is connected Contact an authorised qua lified technical assistance ALAR HOT TEMP The...

Page 9: ...se is completed clean the brazier and start a new light up Switching off while working The stove suddenly switches off while working for example because it has run out of pellets in the tank or because the motor reducer for pellets loading got broken The stove continues working until the pellets left in the brazier ends You will then read the words J P 0M GPC on the display and alarm Wait until th...

Page 10: ...uster to avoid ash to discharge To activate this function press the key and then the key you will read the words PUL STUF cleaning of the stove on the display In order to stop the fan you just need to press the key for a longer time waiting that a cleaning phase is completed 255 seconds EVERY DAY remove and clean the brazier Pict 6 FROM TIME TO TIME clean the exchanger every two days When the stov...

Page 11: ...Notes ...

Page 12: ...l figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot In any case it reserves the right to modify its products as deemed to be required and useful without any prior notification HEATING TECHNIQUE Centrometal d o o Glavna 12 40306 Macinec Croatia central tel 040 372 600 fax 040 372 611 service tel 040 372 622 fax 040 372 621 Notes ...

Reviews: