Centrometal CentroPelet ZV14 Technical Instructions Download Page 6

GB

Heating timer-thermostat

Parameter

Description

Programmable 

values

UT01

฀ ฀

H.  timer-thermostat  ena-
bling and disabling. Day of 
the week setting

UT02

From 00 to 23

Current hour setting

UT03

From 00 to 60

Current minutes setting

UT04

Reserved  

Technical parameters setting

UT05

From 00:00 to 23:50 with 
10-minute steps

Pellet boiler stove first start-
up time adjustment

UT06

From 00:00 to 23:50 with 
10-minute steps

Pellet boiler stove first shut-
down time adjustment

UT07

from 1 to 7

Week  day  selection,  first 
time activation

UT08

From 00:00 to 23:50 with 
10-minute steps

Pellet  boiler  stove  second 
start-up time adjustment

UT09

From 00:00 to 23:50 with 
10-minute steps

Pellet  boiler  stove  second 
shutdown time adjustment

UT10

from 1 to 7

Week day selection, second 
time activation

UT11

From 00:00 to 23:50 with 
10-minute step

Pellet  boiler  stove  third 
start-up time adjustment

UT12

From 00:00 to 23:50 with 
10-minute step

Pellet boiler stove third shu-
tdown time adjustment

UT13

from 1 to 7

Week  day  selection,  third 
time activation

UT14

From 00:00 to 23:50 with 
10-minute steps

Pellet  boiler  stove  fourth 
start-up time adjustment

UT15

From 00:00 to 23:50 with 
10-minute steps

Pellet  boiler  stove  fourth 
shutdown time adjustment

UT16

from 1 to 7

Week day selelction, fourth 
time activation

The  meaning  of  the  user  parameters  are  explained  in  detail 
below:

UT01 
Heating  timer-thermostat  enabling  and  disabling  and 
current hour setting.

This parameter is used to set the current day of the week or 
to deactivate the set programming.
Press buttons        and          to select the desired value as 
shown in the following table:

Upper

Display

MEANING

Day 1

Day 2

Day 3

Day 4

Day 5

Day 6

Day 7

OFF

Example: 

฀ ฀

฀ ฀

start the pellet boiler stove manually (without programming) 
so that the heating timer-thermostat is disabled.

Press button         to go to the following parameter.

UT02 
Current hour setting

This  parameter  is  used  to  set  the  current  hour,  press             
buttons          and        to select the current hour.     
Press button          to go to the following parameter.

UT03
Current minutes setting

Press buttons       and

to adjust current minutes.

Press buttons        to go to the following parameter.

UT04

Technical parameters setting
Press button          to go to the following parameter.

The  heating  timer-thermostat  function  is  used  to  program 
the pellet boiler stove to automatically turn on and off within 
a period of one week.
To access programming, hold down button          for around 
three seconds, “UT01” will be shown on the upper display: 
by pressing button        several times and referring to the 
table  below,  the  stove  can  be  programmed  according  to 
your needs. Press button     to exit the programming phase 
at any time.
These are the heating timer-thermostat parameters:

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

Heating timer-thermostat disabled

Monday

Summary of Contents for CentroPelet ZV14

Page 1: ...NG TECHNIQUE CentroPelet ZV14 TUZS 4 2014 ENG Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 TECHNICAL INSTRUCTIONS for regulation use and maintenance of pellet stove ...

Page 2: ...use and maintenance manual is an integral part of the product Before using installing or servicing the product read the indications contained in this manual carefully This pellet boiler stove should only be used for the intended use it has been designed for Therefore the user shall be responsible for any damage to people animals or things resulting from misuse of the product Installation should be...

Page 3: ...prox Kg 130 80 mm 50 mm 3 4 220V 50Hz 90 W 350 W only start phase 17 kg Weight Flue pipe diameter Air intake pipe diameter Power Supply Min electrical input Max electrical input Hopper capacity Pict 1 Aproximative dimensions mm ...

Page 4: ...e upper display and the system delivery water temperature will be shown on the lower display If the flame does not start up correctly within 10 minutes the pellet boiler stove jams you will read the words 4 on the upper display and the words 01 blinking on the lower di splay Wait 10 minutes until the cooling phase is completed open the door empty the brazier and start a new light up Pict 2 Prelimi...

Page 5: ...the water temperature on the lower display REMARKS The pellet boiler stove is fitted with an automatic device that allows clea ning the brazier after a given period of time when this time is detected the stove fire automatically reduces and 27 4 is shown on the display After some minutes the pellet boiler stove will start working regularly Room temperature range 7 C 40 C WARNING Do not unplug the ...

Page 6: ...ivation The meaning of the user parameters are explained in detail below UT01 Heating timer thermostat enabling and disabling and current hour setting This parameter is used to set the current day of the week or to deactivate the set programming Press buttons and to select the desired value as shown in the following table Upper Display MEANING Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 OFF Example ...

Page 7: ...ay MEANING Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 Lower display In the following example the pellet boiler stove is only star ted on Saturdays and Sundays off 1 off 2 off 3 off 4 off 5 on 6 on 7 Confirm and continue with key If the stove is controlled by an external thermostat when the thermostat reaches the preset temperature 1 6 4 will be shown on the pellet boiler stove display CAUTION the r...

Page 8: ...20 The water temperature exceeds 90 C The cir culating pump is blocked or there is no water in the hydraulic system Check the power supply on the pump Check limestone does not block the pump impeller ALAR SOND H20 The water sensor is not connected There is a short circuit on the water sensor Check the water sensor is connected Contact an authorised qua lified technical assistance ALAR HOT TEMP The...

Page 9: ...se is completed clean the brazier and start a new light up Switching off while working The stove suddenly switches off while working for example because it has run out of pellets in the tank or because the motor reducer for pellets loading got broken The stove continues working until the pellets left in the brazier ends You will then read the words J P 0M GPC on the display and alarm Wait until th...

Page 10: ...uster to avoid ash to discharge To activate this function press the key and then the key you will read the words PUL STUF cleaning of the stove on the display In order to stop the fan you just need to press the key for a longer time waiting that a cleaning phase is completed 255 seconds EVERY DAY remove and clean the brazier Pict 6 FROM TIME TO TIME clean the exchanger every two days When the stov...

Page 11: ...Notes ...

Page 12: ...l figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot In any case it reserves the right to modify its products as deemed to be required and useful without any prior notification HEATING TECHNIQUE Centrometal d o o Glavna 12 40306 Macinec Croatia central tel 040 372 600 fax 040 372 611 service tel 040 372 622 fax 040 372 621 Notes ...

Reviews: