Central Pneumatic 97187 Assembly And Operating Instructions Manual Download Page 3

SKU 97187          For technical questions, please call 1-800-444-3353. 

Page 3

not in use and before connecting to this tool. Do not carry any tool with your finger on the 

trigger, whether it is connected or not.

13. 

Stay alert

. Watch what you are doing, use common sense. Do not operate any tool when you 

are tired.

14. 

Take caution as some woods contain preservatives such as copper chromium arsenate 

(CCA) which can be toxic

. When cutting these materials extra care should be taken to avoid 

inhalation and minimize skin contact.

15. 

Check for damaged parts

. Before using any tool, any part that appears damaged should be 

carefully checked to determine that it will operate properly and perform its intended function. 

Check for alignment and binding of moving parts; any broken parts; and any other condition 

that may affect proper operation. Any part that is damaged should be properly repaired or 

replaced by a qualified technician. Do not use the tool if the trigger does not operate properly.

16. 

Guard against electric shock

.  Prevent body contact with grounded surfaces such as pipes, 

radiators, ranges, and refrigerator enclosures.

17. 

Replacement parts and accessories

.  When servicing, use only identical replacement parts. 

Use of any other parts will void the warranty. Only use accessories intended for use with this 

tool.  All accessories used must be rated 18,000 RPM or greater.  Before each use, inspect 

the accessory for damage or excess wear.  Never use a damage or worn out accessory.

18. 

Do not operate tool if under the influence of alcohol or drugs

.  Read warning labels on 

prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there 

is any doubt, do not operate the tool.

19. 

Use proper size and type extension cord

. If an extension cord is required for the compressor, 

it must be of the proper size and type to supply the correct current to the tool without heating 

up. Otherwise, the extension cord could melt and catch fire, or cause electrical damage to the 

tool.

20. 

Maintenance

.  For your safety, service and maintenance should be performed regularly by a 

qualified technician.

21. 

Use clean, dry, regulated, compressed air at 90 PSI.  

Do not exceed the recommended 

90 PSI.  Never use oxygen, carbon dioxide, combustible gases, or any other bottled gas as 

a power source for this tool.

22.  This tool has no safety shield. 

 DO NOT USE GRINDING DISCS, GRINDING WhEELS OR 

CUT-OFF WhEELS WITh ThIS TOOL.

Note

: Performance of the compressor powering this tool (if powered by line voltage) may vary 

depending on variations in local line voltage. Extension cord usage may also affect compressor 

performance.

WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other con-

struction activities, contain chemicals known [to the State of California] to cause cancer, 

birth defects or other reproductive harm.  Some examples of these chemicals are:

  *Lead from lead-based paints

  *Crystalline silica from bricks and cement or other masonry products

  *Arsenic and chromium from chemically treated lumber

Your risk from these exposures varies, depending on how often you do this type of work.  

To reduce your exposure to these chemicals: work in a well ventilated area, and work with 

approved safety equipment, such as those dust masks that are specially designed to filter 

out microscopic particles. (California health & Safety Code  25249.5, et seq.)
Warning: The warnings, cautions, and instructions discussed in this instruction manual 

REV 01/06; 

REV 03/06

Summary of Contents for 97187

Page 1: ...www harborfreight com Copyright 2004 by Harbor Freight Tools All rights reserved No portion of this manu al or any artwork contained therein may be reproduced in any shape or form without the express...

Page 2: ...do the job better and more safely at the rate for which it was intended Do not modify this tool and do not use this tool for a purpose for which it was not intended 6 Dress properly Do not wear loose...

Page 3: ...ired while taking drugs If there is any doubt do not operate the tool 19 Use proper size and type extension cord If an extension cord is required for the compressor it must be of the proper size and t...

Page 4: ...Air Supply prior to cleaning maintaining or making any adjustments to the tool Step 1 Place the HOLDING TOOL 26 into one of two holes in the SANDING ADAPTER 25 as shown in FIgure 1 Step 2 Open up the...

Page 5: ...NG PLATE Step 6 Thread the ADAPTER LOCK DOWN 27 onto the ROTOR as shown in Figure 2 Tighten Figure 2 Installing the Backing Plate Drill Bit Installation Disconnect the Sander Drill from the Air Supply...

Page 6: ...y Sander Drill Setup Step 1 Set the compressor s pressure regulator to 90 PSI Do not set the compressor s outlet regulator over 90 PSI Step 2 Connect the Sander Drill to the air compressor s hose If l...

Page 7: ...tep 1 Step 7 To begin drilling press the TRIGGER 10 as shown in Figure 5 CAUTION Do not operate the Drill before placing the drill bit on the material Figure 5 Drilling Operations Step 8 Your Sander D...

Page 8: ...heavily or for more than a few seconds at a time Step 6 Every few minutes during continuous sanding check the condition and wear of the sandpaper If necessary peel and replace the sandpaper Do not us...

Page 9: ...ity and durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase This warrant...

Page 10: ...187 For technical questions please call 1 800 444 3353 Page 10 ASSEMBLY DIAGRAM NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement pa...

Reviews: