OPERATION
Step 1: Clamp can firmly by turning the
HANDLE
(#44) as
shown in Figure 1. Do not crush can.
Handle (#44)
Tighten
Adjustment Screw (#07)
NOTE
Clamp mostly empty cans and
aerosol cans with lids toward
clamp handle.
CAUTION
Watch cans while shaking. Make sure
cans do not come loose. Turn Paint
Shaker off immediately if this happens.
Figure 1 — Clamping Paint Can
Step 2: Set Air Compressor’s regulator for 120 PSI and turn on.
Step 3: Allow pressure to build to 120 PSI.
Step 4: Start Paint Shaker by quickly opening the control valve about 1/4 turn.
Step 5: Stop Paint Shaker when done by closing the control valve.
Step 6: Unclamp can. Remove.
Step 7: If rotation is more/less than 15° from side-to-side, screw the
ADJUSTMENT
SCREW
(#07) in/out respectively.
Page #5 -- SKU: 00422