INspEcTION, MAINTENANcE, AND cLEANING
WARNING!
1.
Make sure the air supply hose and water hose are disconnected from
the Angle Grinder before performing any inspection, maintenance, cleaning proce-
dures, or leaving it unattended.
before each use,
2.
inspect the general condition of the Air Grinder. Check for loose
screws, misalignment or binding of moving parts (by rotating the wheel manually),
cracked or broken parts, damaged Cutting Wheel, loose air/water fittings, and any
other condition that may affect the safe operation of the Grinder. If abnormal noise
or vibration occurs, have the problem corrected before further use.
Do not use damaged equipment.
before each use,
3.
rotate the Air Regulator counter clockwise to the shut position.
With the compressor in the off position, and the air supply valve in a closed position,
attach the air hose to the inlet connector. With the water valve in a closed position,
and the water tap closed, attach the water supply hose to the water valve. Open
the water supply to the Grinder, and then open the air supply valve from the com-
pressor. Briefly run the unit. Should you feel any vibration or hear any abnormal
noise, or see any water leakage from the clear water supply tube, abruptly turn the
unit off by disconnecting the air supply hose from the unit, shut the water supply
valve, and disconnect the air and water supply hoses, and have the unit serviced
by a qualified technician.
To clean,
4.
use a clean cloth and mild detergent. Then, dry. Do not use solvents.
Do not immerse the Angle Grinder in liquid.
cAuTION! All maintenance, service, or repairs not mentioned in this manual
5.
must only be performed by a qualified service technician.
TROubLEsHOOTING
problem
possible cause
possible solution
Tool does not run at normal
speed.
Not enough air supply.
1.
Air Regulator closed.
2.
Air supply connection loose.
3.
Lack of lubrication.
4.
Bearings and/or O-Rings worn out.
5.
Adjust compressor regulator to 90 PSI.
1.
Open Air Regulator.
2.
Secure air supply connection.
3.
Make sure an in-line oiler is installed in air
4.
supply line.
Have a qualified service technician replace
5.
Bearings and/or O-Rings.
Automatically starts when
connected to air supply.
Air Regulator open.
Close Air Regulator.
Abnormal vibration. Housing
overheats.
Rotor Blades broken or worn out.
Have a qualified service technician replace Rotor
Blades.
Poor cutting quality.
Dull or defective Cutting Wheel.