Page 11
SKU 96907
For technical questions, please call 1-800-444-3353.
Figure d
Hydraulic Hose Connection diagram, Figure D. Connect the hoses as marked,
(Hose 1 to Connection 1, for example) the hoses will only reach the proper
connections if attached in the proper orientation.
Filling the Hydraulic Fluid
Remove the Hydraulic Oil Cap (20) and fill the tank with Hydraulic oil (not
included). Remove and retain the O-ring
(21).
To check the hydraulic oil level remove
the Dipstick connected to the Hydraulic Oil
Cap, wipe it clean, then dip it back in to
check the level.
The oil should be at the upper notch of
the Dipstick. Be sure that the hydraulic
oil level is between 4. and 8 gallons.
Replace O-ring and Hydraulic Oil Cap.
The hydraulic system must be vented
during operation or it may become
vacuum locked and stop working properly. To vent the system, open the air inlet
hole by loosening the Hydraulic Oil Cap. You may have to move the O-ring to
expose the air inlet vent.
When the Log Splitter is not in operation or being transported, close the air inlet
hole by tightening the Hydraulic Oil Cap.
8.
1.
2.
3.
4.
.
Hydraulic oil
cap (20)
Hydraulic oil
cap (20)