Central Hydraulics 58047 Owner'S Manual & Safety Instructions Download Page 5

Specific Safety Instructions

1. 

The warnings and precautions 
discussed in this manual cannot 
cover all possible conditions and 
situations that may occur.  It must 
be understood by the operator that 
common sense and caution are 
factors which cannot be built into this 
product, but must be supplied by the 
operator.

2. 

Do not adjust the factory set Safety 
Valve.  This valve should only be set 
or reset by a qualified technician.

3. 

This air hydraulic Foot Pump must 
be secured tightly to a stable surface 
to prevent dynamic pressure from 
moving it around during use. Make 
sure there is no tripping hazard.

4. 

Follow manufacturer’s instructions for 
compressor and attachments used.

5. 

Hydraulics must be opened 
and serviced only by a qualified 
technician.

6. 

Only use with hose (not included) and 
other accessories rated to handle 
the forces exerted by this tool during 
operation.  Other accessories not 
designed for the forces generated 
may break and forcefully launch 
pieces.

7. 

Never press the end of the hose (not 
included) against your skin or the 
skin of another person or animal. It is 
possible to inject fluids into your skin 
if using this tool inappropriately.

8. 

Attach all accessories properly to the 
tool before connecting the air supply.  
A loose accessory may detach or 
break during operation.

9. 

Obey the manual for the air 
compressor used to power this tool.

10.  Install in-line shutoff valve to allow 

control over the air supply in an 
emergency, even if a hose is 
ruptured.

Vibration Precautions

This tool vibrates during use.  

Repeated or long-term exposure to 
vibration may cause temporary or 
permanent physical injury, particularly to 
the hands, arms and shoulders.  To reduce 
the risk of vibration-related injury:

1. 

Anyone using vibrating tools regularly 
or for an extended period should 
first be examined by a doctor and 
then have regular medical check-
ups to ensure medical problems are 
not being caused or worsened from 
use.  Pregnant women or people 
who have impaired blood circulation 
to the hand, past hand injuries, 
nervous system disorders, diabetes, 
or Raynaud’s Disease should not 
use this tool.  If you feel any medical 
or physical symptoms related to 
vibration (such as tingling, numbness, 
and white or blue fingers), seek 
medical advice as soon as possible.

2. 

Do not smoke during use.  Nicotine 
reduces the blood supply to the 
hands and fingers, increasing the risk 
of vibration-related injury.

3. 

Wear suitable gloves to reduce the 
vibration effects on the user.

4. 

Use tools with the lowest vibration 
when there is a choice between 
different processes.

5. 

Include vibration-free periods each 
day of work.

Page 5

Item 58047

For technical questions, please call 1-888-866-5797.

Summary of Contents for 58047

Page 1: ...rence 21d When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manua...

Page 2: ...ided could result in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAININ...

Page 3: ...d exposure to high intensity noise is able to cause hearing loss Tool use and care a Use clamps or another practical way to secure and support the workpiece to a stable platform Holding the work by hand or against the body is unstable and is able to lead to loss of control b Do not force the tool Use correct tool for application The correct tool will do the job better and safer at the rate for whi...

Page 4: ...r at the rated pressure or within the rated pressure range as marked on the tool Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated air pressure range b Never use oxygen carbon dioxide combustible gases or any bottled gas as an air source for the tool Such gases are capable of explosion and serious injury to persons SAVE THESE ...

Page 5: ... A loose accessory may detach or break during operation 9 Obey the manual for the air compressor used to power this tool 10 Install in line shutoff valve to allow control over the air supply in an emergency even if a hose is ruptured Vibration Precautions This tool vibrates during use Repeated or long term exposure to vibration may cause temporary or permanent physical injury particularly to the h...

Page 6: ...his air tool may be shipped with a protective plug covering the air inlet Remove this plug before set up Air Supply TO PREVENT EXPLOSION Use only clean dry regulated compressed air to power this tool Do not use oxygen carbon dioxide combustible gases or any other bottled gas as a power source for this tool Adapter Pump 1 Incorporate an in line oiler shut off valve hose regulator with pressure gaug...

Page 7: ...sure gradually while checking the air output gauge to set the right pressure range 8 Inspect the air connections for leaks Repair any leaks found 9 If the tool will not be used at this time turn off and detach the air supply safely discharge any residual air pressure and release the throttle and or turn the switch to its off position to prevent accidental operation Note Residual air pressure shoul...

Page 8: ...ther Valve After use shut the Breather Valve Work Piece and Work Area Set Up 1 Designate a work area that is clean and well lit The work area must not allow access by children or pets to prevent injury and distraction 2 Route the air hose along a safe route to reach the work area without creating a tripping hazard or exposing the air hose to possible damage The air hose must be long enough to reac...

Page 9: ...ual must be performed only by a qualified technician TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn off the tool detach the air supply safely discharge any residual air pressure in the tool and release the throttle and or turn the switch to its off position before performing any inspection maintenance or cleaning procedures TO PREVENT SERIOUS INJURY FROM TOOL FAILURE Do not use damaged e...

Page 10: ...ration as well as abnormal noise or vibration If any of this should occur have the problem corrected before further use Do not use damaged equipment 2 AFTER USE wipe off with a clean cloth Be sure to wipe away any spilled hydraulic fluid 3 MONTHLY check and refill hydraulic fluid See Bleeding Instructions below Bleeding Instructions 1 CAUTION Air may accumulate in the Foot Pedal s system during sh...

Page 11: ... 1 Lubricate using air tool oil and grease according to directions 2 Have qualified technician inspect internal mechanism and replace parts as needed Severe air leakage Slight air leakage is normal especially on older tools 1 Cross threaded housing components 2 Loose housing 3 Damaged valve or housing 4 Dirty worn or damaged valve 1 Check for incorrect alignment and uneven gaps If cross threaded d...

Page 12: ...il Outlet Seat 1 66 Retainer 2 67 O Ring 2 68 Hose Connector 1 69 Lock Nut 1 70 O Ring 2 71 Lever 1 72 Reservoir 1 73 Reservoir Cover 1 74 O Ring 1 75 Nut 1 76 Nylon Ring 1 77 Fill Plug 1 78 Sealing Ring 1 79 Breather Valve 1 80 Base Plate 1 81 Rubber Foot 4 82 Lock Washer 3 83 Screw 3 84 Protective Plug 1 85 Adapter 1 PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PRO...

Page 13: ...ASSEMBLY DIAGRAM Page 13 Item 58047 For technical questions please call 1 888 866 5797 ...

Page 14: ...ord month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts Specify UPC 193175431172 when ordering parts Page 14 Item 58047 For technical questions please call 1 888 866 5797 ...

Page 15: ...e above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or implied including the warranties of merchantability and fitness To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our in...

Page 16: ...26541 Agoura Road Calabasas CA 91302 1 888 866 5797 Page 16 Item 58047 For technical questions please call 1 888 866 5797 ...