FIRESTAR COMBUSTION CONTROLLER - VERSION 6.7 • OPERATION MANUAL
Menu #
Setting
DEFAULT
Min.
Max.
15
ENABLE REMOTE ADJUSTMENT
When set to 1, certain furnace parameters are open to adjustment by
the MyFireStar .com site through the internet . The settings and features
that may be adjusted through the internet will vary depending on the
controller’s current software version number .
0
0
1
16
SYSTEM TEST
When set to 1, a system test in initiated . During the test, press the UP
button as shown on the display to perform each diagnostic test . The last
prompt will display PRESS UP TO EXIT . After exiting the test, turn the
FireStar off and back on to ensure that the furnace returns to normal
operation .
0
0
1
17
N/A (FACTORY HARDWARE CONFIGURATION – DO NOT ADJUST)
-
-
-
18
LOW WATER TEMPORARY OVERRIDE WATER LEVEL SENSOR
Check the water level at the sight gauge and, if necessary, add water
according to the Water Quality and Maintenance section of the Owner’s
Manual . If adding water does not clear the LOW WATER alarm, set this
variable to 1 to temporarily silence a false LOW WATER level sensor
alarm . The controller will operate normally until the next loading (until
the firebox door is left open for more than 30 seconds) . This will allow
operation for one loading (must override each loading) until a repair can
be made . Do not override this alarm if the system has a leak .
NOTE: If water is added to the outdoor furnace and/or system, the system
water should be tested and 1650XL Inhibitor Plus should be added (if
necessary) to maintain the recommended level of protection .
0
0
1
19
ENABLE CELSIUS
When set to 1, all temperatures will be displayed in Celsius . Changing
between Fahrenheit and Celsius will cause any custom temperature
settings to be reset to the factory default settings .
0
0
1
20
EASY REFIRE IDLE PULSE ENABLED
This setting is only utilized when the optional Easy Refire Burn Time Limit
feature has been enabled . When set to 1 and the Easy Refire Burn Time
Limit has been met, the Idle Pulse will be present to maintain active coals
in the portion of the wood load that is being preserved . When set to 0, no
Idle Pulse will be used .
1
0
1
21
EASY REFIRE BURN TIME LIMIT: - - - -
This optional timer-based setting will “shut the furnace down early” in
an effort to preserve a portion of the current wood load until the next
loading . Before adjusting this setting, the operator should have a good
understanding of how the Burn Time Monitor works, as well as a good
understanding of the current heat load on the furnace .
DISABLED
00:15
(0 hours,
15 min .)
99:00
(99 hours,
0 min .)