2
Water Temp
Shows the current reading of the outdoor furnace water
temperature in degrees Fahrenheit.
Fire Temp
Shows temperature reading of the burner. Due to limitations
of the temperature sensor, it is not positioned in the hottest
area of the burner. The actual secondary combustion
temperature may be hotter than what is displayed. This
temperature reading is used the by FireStar II controller to
optimize the performance of the outdoor furnace.
Serial
Shows the serial number of the outdoor furnace that has
been stored in the controller.
Mac Address
This is the unique address of the FireStar XP module.
NOTE:
In order to take full advantage of the FireStar XP’s
online features, you must create an online account and be
connected to a wireless router.
NOTE:
Once you attempt to connect the FireStar XP to your
home’s wi-fi network, it will no longer be set up as a stand
alone network. To set up the FireStar XP as a stand alone
network again, follow these steps:
1. Using the keypad on the FireStar XP, press and hold the
key until #1 is displayed.
2. Press the keypad
or
key until #9 is displayed; then
press the
key.
3. Press the keypad
or
key to set the value to 1
(signifies setup/stand alone network mode).
4. Press the
key.
5. Wait a few moments while your FireStar XP restarts. Once
the blue LED stops flashing and remains on, the FireStar
XP is in Setup/Stand Alone Network Mode.
Summary of Contents for Fire Star XP
Page 4: ......