background image

14

14

Zephiro Fog 3000 User Manual

Eng

When adding fluid, remember to turn power off, and carefully avoid spilling over 

to cause short circuits.

 

y

The fog machine should work under professional operator’s supervision, please 

do not add flammable liquids or gas into the fog fluid tank.

 

y

When you don’t use the machine for long time or after use, please disconnect 

power or unplug the power cable. After using, please wipe out the liquid in the 

tank, as it would avoid the housing to be corroded.

 

y

All fog machines will have condensation or moisture around the Output Deflec-

tor.

 

y

All fog machines have heating-cooling cycles. When internal temperature drops 

to minimum, the pump automatically turns on and begins heating. Once heating 

is complete, the machine starts to spray fog again.

 

y

In the case of a serious operating problem, stop using the unit immediately. 

Never try to repair the unit by yourself Repairs carried out by unskilled people 

can lead to damage or malfunction. Please contact the nearest authorized tech-

nical assistance center  Always use the same type of spare parts

 

y

Never connect the device to a dimmer pack.

 

y

Make sure the power cable in never crimped or damaged and never disconnect 

it by pulling or tugging on the cable.

 WARNING: Fog machines may set off Smoke Alarms.

6.1. Routine Maintenance And Common Faults

 ATTENTION: Periodically clean your machine to reduce replacement parts and 

repair expenses.

 

y

Poor fog liquid can cause blockage. It is recommended to use high quality fog 

liquid.

 

y

The machine might get blocked due to high concentration fluid, not-pure fluid 

or overheat, so regular care and maintenance can ensure long-term use. After 

about 40 hours continue use, please prepare an 80% distilled water and 20% 

white vinegar blend to remove any accumulated impurities inside boiler and 

pipe, as following:

 

y

Wash the pipe in the tank and its filter head.

 

y

Pour out any liquid inside, and replace with the cleaning liquid (80% distilled 

water and 20% white vinegar), turn on power, keep it operating till the cleaning 

liquid runs out.

 

y

If the fog turns less, and the pump makes noise, switch off the unit immediately 

and check fluid level, fuse, controller interface and power plug. If all of these are 

normal, please connect power again. If problems still continue, please contact 

the supplier.

Summary of Contents for ZEPHIRO FOG 3000

Page 1: ...re of it Leggete questo manuale e conservatelo per future consultazioni User Manual Manuale Utente 3000 Watt Fog Machine with DMX wired and wireless control Macchina per Fumo da 3000W con controllo DM...

Page 2: ...ever closer to professional s real requirements The Centolight Team Gentile Cliente Grazie per aver scelto un prodotto Centolight La nostra missione quella di sod disfare ogni possibile richiesta da p...

Page 3: ...2 Safety Notes 5 3 Introduction 7 3 1 Features 8 3 2 Product Dimensions 8 3 3 Rear Panel 8 4 Product Overview 9 4 1 Mains Power Fuse 9 4 2 DMX Connection 9 4 3 DMX Terminator 10 4 4 3 Pin vs 5 Pin DMX...

Page 4: ...he product and included accessories appear damaged from shipping or show signs of mishandling notify the carrier or dealer seller immediately In addition keep the box and contents for inspection 1 3 A...

Page 5: ...id touching the nozzle This symbol indicates a protective grounding terminal WARNING Describes precautions that should be observed to prevent the danger of injury or death to the operator To protect t...

Page 6: ...limate to the surrounding environment before connecting it to power y Do not use in a confined space Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjace...

Page 7: ...manufacturer Only use accessories attachments or parts recommended by the manufacturer 3 Introduction It is well known how the world of show business and entertainment is based on the fusion of music...

Page 8: ...trol smoke emission y Wired Controller to manage Timer Duration and Volume of smoke emission y Remote controller to start and stop the smoke emission 3 2 Product Dimensions 300mm 11 8 703mm 27 7 100mm...

Page 9: ...fuse make sure that the appli ance is switched off disconnect the input power plug and unscrew the fuse holder cover shown above with a Phillips screwdriver CAUTION Replace the fuse ONLY with one of...

Page 10: ...ion is pin 1 while pin 2 is Data Nega tive S and pin 3 is Data positive S CAUTION Wires must not come into contact with each other otherwise the fix tures will not work at all or will not work properl...

Page 11: ...LR plug Pin 1 GND Screen Pin 2 Signal Pin 3 Signal 5 Setting Up ZEPHIRO 3000FOG can be hanged up in high places with clamps or couplers not included or placed on the ground Keep it in horizontal posit...

Page 12: ...termines the duration when timer is active fog emission 3 Output intensity knob Adjusts fog emission from 0 to 100 4 Timer function on off switch 5 Continuous fog switch When active the machine emits...

Page 13: ...ot oper ates please check whether battery is low and need to be replaced To change the battery remove the cover on the back of the remote control and replace the old battery with one of the same type...

Page 14: ...the same type of spare parts y Never connect the device to a dimmer pack y Make sure the power cable in never crimped or damaged and never disconnect it by pulling or tugging on the cable WARNING Fog...

Page 15: ...d permanent damage to the internal electronics and heating elements 7 Specification Heating Element 3000 Watt Output distance 8 10 meters Warm up time Approximately 4 Minutes Tank capacity 10 Liters F...

Page 16: ...CENTER Via Enzo Ferrari 10 62017 Porto Re canati Italy In order to send a product to service center you need an RMA number Shipping charges have to be covered by the owner of the product For further i...

Page 17: ...21 3 1 Caratteristiche 22 3 2 Panoramica del Prodotto 22 3 3 Dimensioni del Prodotto 22 4 Panoramica del Prodotto 23 4 1 Cavo di Rete e Fusibile 23 4 2 Connessioni DMX 23 4 3 Terminatore DMX 24 4 4 Ca...

Page 18: ...immediatamente il vettore o il rivenditore e conservare la scatola e il contenuto per una eventuale ispezione Se l apparecchiatura dovesse essere restituita importante farlo nell imballo ori ginale Si...

Page 19: ...are attenzione alle alte temperature ed evitare di toccare l ugello Questo simbolo indica un terminale di messa a terra ATTENZIONE Descrive precauzioni da osservare per prevenire lesioni o morte dell...

Page 20: ...di provocare guasti consentire al prodotto di acclimatarsi completamente all ambiente circostante prima di collegarlo all alimentazione y Non utilizzare in uno spazio ristretto Installare sempre il p...

Page 21: ...o accessori collegamenti o parti raccomandati da CentoLight 3 Introduzione E noto come il mondo dello spettacolo e dell intrattenimento si basi sulla fusione tra musica immagini luci ed effetti ambien...

Page 22: ...y Canale DMX per controllare l emissione di fumo in uscita y Comando a filo con Timer la durata e quantit di fumo y Radiocomando per attivare e disattivare l emissione 3 2 Panoramica del Prodotto 300...

Page 23: ...ssario sostituire il fusibile assicurarsi che l apparecchio sia spento scollegare la spina di alimentazione in ingresso e svitare il coperchio del porta fusibile mostrato sopra con un cacciavite a ste...

Page 24: ...nessione dello schermo il piedino 1 mentre il piedino 2 negativo S e il piedino 3 positivo S ATTENZIONE I fili non devono entrare in contatto l uno con l altro altrimenti i dispositivi non funzioneran...

Page 25: ...3000FOG pu essere appesa in alto con morsetti o giunti non inclusi o posizionato a terra Tenere il dispositivo in posizione orizzontale non inclinare o capovolgere Prima di collegare alla rete riempi...

Page 26: ...di attivazione del timer emissio ne di fumo 3 Intensit di uscita Regola l emissione di fumo da 0 a 100 4 Timer On Off Interruttore on off della funzione timer 5 Tasto per emissione continua quando at...

Page 27: ...ia non sia scarica e deve esse re sostituita Per cambiare la batteria rimuovere il coperchio sul retro del teleco mando e sostituire la vecchia batteria con una dello stesso tipo 23A 12V AVVISO Presta...

Page 28: ...i a causa di fluido ad alta concentrazione di fluido non puro o di surriscaldamento pertanto una cura e una manutenzione regolare possono garantire il funzionamento pi a lungo Dopo circa 40 ore di uso...

Page 29: ...acit del serbatoio 10 Litri Emissione fumo 710m Min Consumo Liquido Fumo 2L ora a seconda della densit del liquido usato Indicatore di Macchina pronta SI LED a due colori Radiocomando 433 92 MHz Max 1...

Page 30: ...10 62017 Porto Reca nati Italia Per inviare un prodotto al centro di assistenza necessario un numero di RMA Le spese di trasporto devono essere coperte dal proprietario del prodotto Per ulteriori info...

Page 31: ...otto viene importato nella UE da FRENEXPORT SPA Via Enzo Ferrari 10 62017 Porto Recanati Italy www centolight com CentoLight is a registered trademark of FRENEXPORT SPA Italy CentoLight un marchio di...

Page 32: ...Ver 1 0 July 2022 www centolight com...

Reviews: