background image

CENGAR

 

SAWS

  

 

are

 

hand

 

held

 

reciproca ng

 

saws

 

designed

 

to

 

cut

  

metals

 

and

 

plas cs

 

in

   

produc on

 

environments

 

and

 

can

 

be

 

used

 

in

 

Atex

 

zoned

 

areas

 

where

            

appropriate.

 

They

 

should

 

only

 

be

 

used

 

by

 

trained

 

operators

 

who

 

are

         

responsible

 

for

 

the

 

safety

 

of

 

themselves

 

and

 

others

 

in

 

the

 

vicinity.

 

Saw

 

blades

 

are

 

capable

 

of

 

causing

 

serious

 

injury

 

Think

 

safe

 

  

Act

 

safe

 

 

Be

 

safe

 

 

LUBRICATION

 

 

Use Cengar Green Oil with longer las ng coa ng proper es for best 
results. Cengar Green Oil is specially prepared to: 

 

 

Emulsify the water generally found in compressed air lines.

 

Give perfect mist lubrica on.

 

Remain 

fl

uid at the low working temperature of compressed air tools.

 

Contains corrosion and oxida on inhibitors.

 

 

Incorrect oils if used will soon “break down” forming a sludge which will 
slow and eventually stop the ac on of the saw. See  maintenance details. 

 

INSTALLATION

 

OF

 

BLADES.

 

 

Before a emp ng to insert or change a blade, ensure that the air supply is 
isolated by opera ng the isola on valve provided. Loosen the retaining 
grub screws with the key provided, insert blade through nosepiece so that 
the teeth are cu ng on the pull stroke. 

 

Locate the back screw in the hole in the end of the blade, for a posi ve 
drive, the front screw can then be  ghtened to grip the blade 

fi

rmly. 

 

BLADES

 

 

Cengar “Sha erproof” Bi

Metal blades are specially prepared for use with 

Cengar saws, to withstand the high opera ng speeds, and  give maximum 
cu ng life. 

 

Choose the teeth per inch to suit the characteris cs of the material being 
cut. 
Choose pitch to ensure that at least 3 or 4 teeth are cu ng at the same 

me. 

Summary of Contents for CL50

Page 1: ......

Page 2: ...6 42 EC EN ISO 11148 12 2012 Handheld non electric power tools EN ISO 13753 2008 Mechanical Vibra on and shock Atex Direc ve 2014 34 EU Based on the following Harmonised Standards EN13463 1 2009 And therefore complies with the essen al requirements of those direc ves Addi onal Informa on ATEX Coding II 2G T5 X Technical filie lodged with Element Materials Technology 0891 Technical File number CEEX...

Page 3: ... should be followed as per the Health and Safety at Work Act We recommend that Eye protec on be worn when using Cengar Saws We recommend normal safe working prac ces should be followed as per the Health and Safety at Work Act or the appropriate Na onal and State Laws We recommend that eye and ear protec on be worn when using Cengar Saws Each machine is marked with a unique serial number which cont...

Page 4: ...n inhibitors Incorrect oils if used will soon break down forming a sludge which will slow and eventually stop the ac on of the saw See maintenance details INSTALLATION OF BLADES Before a emp ng to insert or change a blade ensure that the air supply is isolated by opera ng the isola on valve provided Loosen the retaining grub screws with the key provided insert blade through nosepiece so that the t...

Page 5: ...Ohm resistance between the ground at the air source and any metallic object to be cut with the equipment 3 The Saw shall be firmly abu ed to the work piece before opera on and quenched with liquid during opera on The saw is HUMAN OPERATOR CONTROLLED and THE OPERATOR MUST ENSURE LUBRICATION OF THE BLADE AT ALL TIMES The operator must stop the saw immediately if there is no lubrica on 4 The equipmen...

Page 6: ...CL 50 75 Exploded View ...

Page 7: ... 25 1147 Centre Sha 1 8 9560 O Ring Small 2 26 55516 Screws for above 2 9 9557 Détente Spring 1 27 1150 Link to Pistons 1 10 9556A Lock Screw 1 28 1148 Top Piston 1 2 to 10 9552 Isolator Assembly 29 1152 Bo om Piston 1 11 51834 Roll Pin Trigger 2 30 1147 Pin to Link 2 12 50034 Valve in Handle 1 31 1147 Pin to Pedestal 1 13 9502 Trigger 1 32 1153 5 Pedestal 1 14 9506 Filter Gauze 1 33 5540 Screw Ha...

Page 8: ...CL 50FT 75FT Exploded View ...

Page 9: ... 25 1147 Centre Sha 1 8 9560 O Ring Small 2 26 55516 Screws for above 2 9 9557 Détente Spring 1 27 1150 Link to Pistons 1 10 9556A Lock Screw 1 28 1148 Top Piston 1 2 to 10 9552 Isolator Assembly 29 1152 Bo om Piston 1 11 51834 Roll Pin Trigger 1 30 1147 Pin to Link 2 12 50034 Valve in Handle 1 31 1147 Pin to Pedestal 1 13 9502FT Trigger 1 32 1153 5 Pedestal 1 14 9506 Filter Gauze 1 33 5540 Screw ...

Page 10: ...this will bring the link shoulders clear of the cylinder walls 2 Remove the centre sha by firstly removing the two retaining screws Part No 55516 and pushing the sha out carefully 3 Push the top piston forward the bo om piston will follow un l everything comes out 4 Before refi ng ensure that each piston is a smooth sliding fit in it s own bore without being able to feel slackness 5 Insert the pis...

Page 11: ...he carrier over the front end tube all the way to the back and clamp ght with the Allen key provided 3 Slide on the new shortened silencer and refit the nosepiece The clamp carrier can remain on the saw for normal use when the clamp is not in use Always remove the saw from the airline before commencing any maintenance work Only fit genuine Cengar parts and accessories or safety may be compromised ...

Page 12: ...nternal parts with anything other than a clean lint free cloth and M S Cleaner or Cengar Green oil 9 NEVER modify Cengar saws or use non Cengar parts this will invalidate ATEX approval and warranty ALWAYS 1 ALWAYS use Cengar green oil for best results Keeping the saw clean and well oiled will give excellent reliability and a long life 2 ALWAYS use Cengar Bi Metal Sha erproof blades for safety and ...

Page 13: ...ng thicknesses of material in situ work can be done in ght spaces or very narrow trenches due to the compact actuator design Hand arm vibra on figures are reduced to Zero Cuts are kept square ready for weld joints Needs only 95mm of pipe length exposed Gives faster cu ng and extends blade life Operators are free to stand clear or prepare Complete power feed clamp CP1P As above plus CL75 mount kit ...

Page 14: ...nal extras 9507CFA Op onal fall arrester plug to a ach to spring balance 1139FA Op onal Fall Arrester Bracket to a ach to spring balance LUB01 Op onal In Line lubricator 28cc capacity runs full day per fill ...

Page 15: ...es and types available on request Cengar Green Oil GO 9107P Cengar Green Oil 250 ml plas c bo les for all air tools GO 9109 As above in 5 litre container GO 9110 As above in 25 litre container M S Cleaner MS 9105 1 litre General purpose cleaning fluid for air tools MS 9125 50 ml In a dropper bo le Enough for 10 tools Always use plenty of Cengar green oil a erwards Nosepiece 5045 Replacement nosepi...

Page 16: ...77161 enquiries cengar com www cengar com SERVICE We offer a full factory repair and refurbishment service for Cengar Saws normally within 5 working days Quota ons at no charge can be given before work is carried out DISTRIBUTOR ADDRESS Original Instruc ons Document No MAN5075ENG 01 Issue 09 July 15 ...

Reviews: