7
1. GENERAL CHARACTERISTICS
Rechargeable battery:
Type
CB3662L (Li-Ion)
Voltage / Current / Energy
V / Ah / Wh
36 / 6,2 / 223,2
Weight
kg
1,6
Drilling Machine:
SD-19BR SD-19BR-RP
SD-19BRA SD-19BR-RPA
SD-19BRT SD-19BR-RPT
SD-19BR2E
SD-19BR2-RPE
Rated drilling capacity
Ø mm
28
Drilling thickness
mm
200 *
Rated no load speed n
0
(spindle)
RPM
700
Brushless electric motor
V
36
Weight with battery
Weight with battery (
RP
versions )
kg
kg
16.8
17.4
Dimensions
Ref. to page 23
Operating temperature
°C (°F)
-20 to +50 (- 4 to +122)
Supplied TPM guard nozzle
type
TPM200-26 **
TPM190-24 **
Air Noise
(1)
Air Noise
(1)
(
RP
versions )
dB
dB
L
pA
80.4 (A) L
pCPeak
97.5 (C) L
WA
88.4 (A)
L
pA
77.6 (A) L
pCPeak
94.4 (C) L
WA
88.5 (A)
Vibrations
(2)
m/s
2
a
h
1.36 max.
* Using Cembre PV... augers series with standard lenght of 325 mm. Depending on the PV... auger usage, higher drilling
thicknes-
ses are possible (Ref. to § 10).
** TPM200-26: suitable for augers having ø max. 20 mm and centering for ø 26 mm plate hole.
TPM190-24: suitable for augers having ø max. 19 mm and centering for ø 24 mm plate hole.
(1)
Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u
L
pA
= weighted continuous acoustic pressure level equivalent.
L
pCPeak
= maximum value of the weighted acoustic displacement pressure at the work place.
L
WA
= acoustic power level emitted by the machine.
(2)
Directive 2006/42/EC, annexe 1, point 2.2.1.1
Weighted root mean square in frequency of the acceleration the upper limbs are exposed to for each biodynamic
reference axis. Tests carried out in compliance with the indications contained in EN ISO 5349-1/2 Standard, and
under operating conditions much more severe than those normally found.
ENGLISH