15
1.11.4
Setting the Label Sensor
The label sensor can be shifted perpendicular to the direction of paper
fl
ow for adaptation to the media. The sensor
unit (1) of the label sensor (Ref. to Fig. 10) is visible from the front through the print unit and is marked with an inden-
tation in the label sensor retainer. When the printer is switched on, a yellow LED illuminates the sensor position.
Loosen screw (4).
Position label sensor with tab (5) in such a way that the sensor (1) can detect the label gap or a re
fl
ex or perfo-
ration mark.
In Figures 11 and 12 there are some examples showing the right positioning of the l
abel sensor (1)
depending on the
type of material being printed
.
Figure 11
Examples of label sensor setting
(*)
Some versions of cable markers KM-ROLL are equipped with a transversal black line mark instead the lateral perforation mark,
in such a
case position the label sensor centrally on a marker
.
In case of continuous
fi
lm TTF or continuous strip STRIP-ROLL, position the label sensor (1) at any point on the
material.
Figure 12
Examples of label sensor setting
Loading Material
4
4.1.3
LABEL SENSOR
POSITION
LABEL SENSOR
POSITION
LABEL SENSOR
POSITION
LABEL SENSOR
POSITION
TTL.....
TPM-ROLL.....
ETF-ROLL.....
KM-ROLL..... (*)
LABEL SENSOR
POSITION
LABEL SENSOR
POSITION
TTF...
STRIP-ROLL...