13. MAINTENANCE
Before you service or remove parts, stop the engine and allow it to cool.
Always remove the spark plug cap from spark plug when servicing the engine
to prevent accidental starting.
After the first 10 operating hours, proceed with oil sump change, as follows
(Ref. to Fig. 26a and 26b):
– Remove the cap with the magnetic insert (24).
– Remove the oil filler cap (08).
– Make sure that all the oil comes out by slightly tilting the
drilling machine in order to make the operation easier.
– Clean the cap (24) (see §
13.1.2
).
– Reassemble the cap.
– Fill up the oil sump to the level indicator (see §
13.1.1
)
using the oil supplied with the drilling machine; it will be
necessary to use about 100 ml.
– Replace the oil filler cap (08).
Ensure that disposal of used oil is in accordance with cur-
rent legislation.
13.1) ORDINARY MAINTENANCE OF THE MACHINE
Every 20 hours of operation
13.1.1) Topping up oil
(Ref. to Fig. 26a and 26b)
With the drill switched off and placed on a flat surface,
check the oil level in the crankcase by looking through the
transparent inspection cover (16).
The level must be approximately half way up the cover; if the
level is low, top up the oil by unscrewing the cap (08) at the
top of the crankcase and adding the quantity of oil required.
Only use the oil grade recommended in § 1.
Never use regenerated or used oil.
The oil must be clean.
08
16
24
FIG. 26a
FIG. 26b