18
6.2
Start process is not being initiated
If the conductor is inserted, the EPB-1N will not start.
Check the front door
•
Check that the front door (1) is completely closed and locked.
Check the air pressure
•
Check that the air pressure at the manometer (1) is 5 bar:
No pressure present:
•
Check whether the compressed air connection is connected to
the compressed air supply.
•
Check whether the compressed air supply is OK.
Pressure is not 5 bar:
•
Disconnect the compressed air connection.
•
Pull the air pressure regulator (2) upwards.
•
Set the air pressure by turning (3) to the right (+) or left (-).
•
Then press the regulator (4) downwards.
Check sleeve receiver
•
Pull the release lever (1) forwards.
•
Remove the reversing base sleeve (2) downwards.
•
Check that the sleeve receiver (3) is positioned correctly and
is snapped into place in the ball latch.
•
Install sleeve receiver.
Close front door.
6.3 Conductor insulation is not removed completely
Check cross section
•
If the conductor isn't properly stripped, first check that the EPB-1N is fitted with
the correct retrofit kit.
•
Adjust the retrofit kit to suit the selected conductor cross section (see page 14).
•
Also check the conductor cross section.
•
If the the malfunction continues despite having the correct retrofit kit, check the
stripping blade (see page 12).
WARNING: Risk of injury!
Disconnect the mains plug and the compressed air
before you open the front door.
1