background image

ENGLISH

Installation manual  Ver. 05-2017

SE2-MOUNTING

A

B

C

D

E

Si rac

comanda tassativamente la verifica periodica (mensile) del corretto serraggio del terminale SE2 (780N m 575Ft Ibs). 

Un serraggio errato può provocare imprecisioni di equilibratura e danni alla macchina NON COPERTI DA GARANZIA.

We strongly  recommend a periodic (monthly) testing of the proper tightening of the SE2 terminal (780N m 575Ft Ibs). 
A bad tightening can cause balancing inaccuracies and machine damages NOT COVERED BY WARRANTY.

Nous recommandons fortement la vérification périodique (mensuel) du correct serrage du terminal SE2 (780N m 575Ft Ibs). 
Un mauvais serrage peut entraîner des imprécisions d’équilibrage et dommages à la machine PAS COUVERTS PAR LA GARANTIE.

Eine regelmäßige (monatliche) Kontrolle der richtigen Befestigung des Endstücks SE2 wird unbedingt empfohlen. 
Eine falsche Befestigung kann zu einer ungenauen Auswuchtung und zu Maschinenschäden führen, die NICHT VON DER GARANTIE GEDECKT SIND.

Es muy recomendable una prueba periódica (mensual) del correcto apriete del terminal SE2 (780N m 575Ft Ibs). 
Un mal ajuste puede perjudicar la calidad del equilibrado y causar daños a la máquina NO CUBIERTO POR LA GARANTÍA.

É altamente recomendável um teste periódico (mensal) o aperto adequado do terminal SE2 (780N m 575Ft Ibs). 
Um mau aperto pode causar imprecisões equilíbrio e danos à máquina NÃO COBERTOS PELA GARANTIA.

0mm

CH13

CH17 (50Nm)

12

Installation

Summary of Contents for EZ10

Page 1: ...3826 Mandello del Lario LC ITALY Telefono 39 706369 Fax 39 0341 700725 www cemb com garage cemb com The Manufacturer declines all liability for any damage to people or property caused by incorrect use...

Page 2: ...ruzioni originali Translation of the original instructions Traduction de la notice originale bersetzung der Originalanweisungen Traducci n de las instrucciones originales Tradu o das instru es origina...

Page 3: ...easures 4 2 7 AIRBORNE NOISE EMISSION 5 2 8 OPERATOR WORKING POSITION 5 3 UNPACKING AND POSITIONING 6 3 1 VISUAL INSPECTION 6 3 1 1 Checking the machine and equipment supplied 6 3 2 UNPACKING 6 3 3 PA...

Page 4: ...the only reference to resolve any interpretation controver sies related to the translation into the European Community languages This publication forms an integral part of the machine and must theref...

Page 5: ...nal education training and experience as well as knowledge of the standards requirements and provisions for accident prevention In addition the operator assigned based on the above must be specificall...

Page 6: ...safety devices or ignore warnings and alarms be they communicated by the software or by warning labels fixed on the installation Should the plates adhesive labels decals or any other warning sign on...

Page 7: ...ing operation the machine noise is subordinate to the background noise in the workplace the presence of other machines and other factors that cannot be assessed by the manufacturer in advance The user...

Page 8: ...as well as the EC declaration of conformity or alternatively the declaration of the Manufacturer In the event of defects and or missing material immediately notify the manufacturer and follow his ins...

Page 9: ...agents and with the following characteristics Ambient conditions as described above Positioned in such a way that it is protected against deformation crushing breakage etc Not subjected to knocks vibr...

Page 10: ...leave a space of about 1 metre around the machine the place where the machine is installed must be free of corrosive explosive powders or gas the place of installation must be vibration free the ligh...

Page 11: ...ENGLISH Installation manual Ver 05 2017 XX XX XX XX XX XX XX XX XX XX 9 4 Installation WARNING Pay attention to what is specified on the stickers below reserved for the market USA Installation...

Page 12: ...ENGLISH Installation manual Ver 05 2017 Hz KW VERSION MODEL SER N V PHASE Year T C V A XXXXX 04PRB0568 XXXXX 10 Installation...

Page 13: ...A EMS LR air currents or forced ventilation in the direction of the device may cause malfunctions or incorrect readings WARNING Shouldatthetimeofinstallationtheambientconditionsbedifferentfromthosepre...

Page 14: ...t Ibs Un mauvais serrage peut entra ner des impr cisions d quilibrage et dommages la machine PAS COUVERTS PAR LA GARANTIE Eine regelm ige monatliche Kontrolle der richtigen Befestigung des Endst cks S...

Page 15: ...ENGLISH Installation manual Ver 05 2017 SE2 DISMOUNTING A B C D E CH13 CH17 13 Installation...

Page 16: ...that the wire cross section may not be less than 2 5 mm2 Make sure that the extension is arranged so that it does not constitute a risk or obstruction WARNING The connection to the single phase mains...

Page 17: ...oper working methods and practices Pay attention to the position of your hands in the areas indicated in the figure as there is a risk of crushing your fingers during wheel locking on the spindle Whil...

Page 18: ...ENGLISH Installation manual Ver 05 2017 16...

Reviews:

Related manuals for EZ10