10. Unpack the power conditioner and place it on the work bench or the floor as far away from the SMART Trac II
Magnet as possible.
Ensure that the power conditioner is not placed in close proximity with the SMART Trac II magnet to prevent
demagnitization of the magnet.
11. Carefully connect each cable provided in the SMART Trac II cable kit and the cable in the accesssory kit. Ensure that
each cable is connected properly. (Refer to the illustration on pages 4 and 5. Use caution to prevent bending or
damaging the pins of the connectors.
12. Unpack the heater and heater block. Plug the heater power cord into one of the receptacles of the power conditioner
as illustrated on page 4. Place the heater block inside the heater. Press the “Power” button first, then press the
“On/Off” button as illustrated below. Follow the manufacturer’s instructions included with the heater block to set the
temperature of the heater to 40 °C. Place the Trac Standards (p/n 160065 and 160570) in the heater block and
permit the standards to heat for at least four (4) hours. Note: The label on the bottom of the heater indicates the
actual voltage
CAUTION
13. Plug the power cords from the SMART Turbo and the processor module into the power conditioner.
14. Plug the power cord of the power conditioner into the appropriate electrical outlet. Turn the power conditioner on.
Note:
The above power cord is applicable to the U.S. only. Power cords for instruments installed in other countries will be
supplied based on electrical specifications for the applicable country.
15. Position the power switch of the SMART Turbo and the SMART Trac II processor module in the “on” position.
Note:
CEM Corporation recommends that the SMART Trac II System power cords be connected to electrical outlets and
the power switches remain in the “on” position at all times. After 15 minutes of idle time, the SMART Turbo assumes a
“sleep” mode.
ON
OFF
6
Summary of Contents for Smart Trac II
Page 1: ...Corporation Quick Start Guide 600269 Rev 1 ...
Page 8: ...System Setup ...
Page 9: ...SMART Trac II Setup Guide ...
Page 12: ...3 Right click SMARTNMR and select Tools System Setup ...
Page 13: ...4 Select on System Setup ...
Page 16: ...SHIM Setup prompt for Oil Standard Cal lock prompt for Normalization Standard ...
Page 23: ...Method Importation ...
Page 25: ...Method Creation ...