background image

9

Operating Instruction for Thermal Imager

4.Structure Description

  1-Visual Camera
  2-Infrared Camera Lens
  3-Dust Cover Lanyard Hole
  4-Trigger
  5-Interface and Cover
    5.1-Type-C USB/Charge
    5.2-Micro SD Card Slot

6-LCD Display and Touch Screen
7-Images Browse Button
8-Power/Lock Button
9-Menu/Select Button
10-Up/Down/Right/Left Button
11-Battery
12-Triangular Bracket Fixed Hole

5.2

5.1

1

4

2

3

5

6

7

8

9

10

11

12

Summary of Contents for DT-986H

Page 1: ...Operating Instruction for 256 x 192 Pixels Thermal Imager Please read this manual before switching the unit on Important safety information inside...

Page 2: ......

Page 3: ...Shutter 5 7 TemperatureMeasurement 5 8 Emissivity Adjustment 5 9 Reflected Temperature 5 10 Thermal Imager Reporter Software 6 Menus 6 1 Main Menu 6 2 Image Mode 6 3 Image Palette 6 4 Image Adjustmen...

Page 4: ...Mode 6 8 6 Change Color 6 9 Video Menu 6 10 Files Browser 6 10 1 Analyse an Image 6 10 2 Play a Video 6 10 3 View Image Info 6 10 4 Delete a File 6 11 USB Mode 7 Fault Diagnosis and Exclusion 8 Androi...

Page 5: ...Thermal Imager Only use the correct equipment to discharge the battery If you do not use the correct equipment you can decrease the performance or the life cycle of the battery If you do not use the...

Page 6: ...clean the infrared lens too vigorously This can damage the anti reflective coating Take the Thermal Imager from from cold to hot it will appear condensation in thermal Imager To protect the Thermal Im...

Page 7: ...Uncooled microbolometer 8 14 m 256x192 pixels 3 5in LCD 640x480 pixels Touch screen IR image Visual image Picture in picture Auto fusion zoom IRON Rainbow Grey Grey Inverted Brown Blue red Hot cold F...

Page 8: ...Temperature Range Humidity Operating and Storage Drop Test Bump Vibration Physical Data Camera Weight Incl Battery Camera Size L x W x H 2 Megapixels FOV 65 USB Type C Data transform between camera an...

Page 9: ...3 Dust Cover Lanyard Hole 4 Trigger 5 Interface and Cover 5 1 Type C USB Charge 5 2 Micro SD Card Slot 6 LCD Display and Touch Screen 7 Images Browse Button 8 Power Lock Button 9 Menu Select Button 10...

Page 10: ...es the charge icon not changed 3 Disconnect ac power adapter when the battery is full charged Note Make sure that the Thermal Imager is near room temperature before you connect it to the charger Do no...

Page 11: ...4 Desktop The Desktop is as follow 1 Temperature Unit 2 Distance Unit 3 Emissivity 4 Zoom Indicator 5 SD Card 6 Wifi Status 7 Battery Capacity Status 8 Time 9 Main Menu 10 Centre Point Temperature Re...

Page 12: ...ally while The thermal image of the Thermal Imager becomes blurry 5 7 Temperature Measurement All objects radiate infrared energy The quantity of energy radiated is base on the actual surface temperat...

Page 13: ...emissivity the more potential error is associated with the Imager s temperature measurement calculations This is also true even when adjustments to the emissivity and reflected background adjustments...

Page 14: ...issivity The reflected temperature can be set individually Follow these steps to get the right value for the reflected temperature 1 Set the emissivity to 1 0 2 Adjust the optical lens to near focus 3...

Page 15: ...alculation and display of radiometric temperature measurement data related to the thermal images Image Mode Set image source for the display on the Thermal Imager s LCD It contains five items such as...

Page 16: ...to Fusion Measuring Distance Thermal Sisplays only infrared image Visible Displays only visible image Picture in Picture Display fusion image of infrared and visible images AUF Auto Fusion mode compar...

Page 17: ...tion for Thermal Imager Zoom Mode In this mode the image can be zoom in out continuously In the Zoom mode Press Left key or slide the zoom bar to zoom in the image Press right Key or slide the zoom ba...

Page 18: ...main menu press Palette icon button highlight Palette 2 Press Up Button popup Image submenu which contains 8 kinds of color palettes and 4 kinds of special palettes 3 Press Left or Right Button or to...

Page 19: ...palette other part of the image will displayed as visible image 6 4 Image Adjustment There are three kinds of mode for image adjustment hisgram Auto and Manual 6 4 1 Lock Operation Press Power Lock Bu...

Page 20: ...and Auto Mode Auto Mode level and span are decided by the thermal image of minimum temperature and maximum temperature The relationship between temperature and color is linear Histgram Mode the therm...

Page 21: ...abled after you choose it Center Spot Measure the center point temperature Manual Spot Measure the manual point temperature There are three manual analyse points Line Analsye Measure the line temperat...

Page 22: ...re submenu press Left and Right arrow to change the temperature values The reflective temperature is important for radiometric temperature measurement Thermal Imager has temperature compensation for r...

Page 23: ...e s accurate the compensation humidity can be set from 10 100 6 6 4 Delta Temperature Compesation In delta temperature submenu press Left and Right arrow to change the temperature values 6 6 5 Distanc...

Page 24: ...ange the emissivity values Emiss sets object emissivity the value range is 0 01 1 00 6 7 Settings Menu 1 In main menu press Settings icon button highlight Settings 2 The Settings menu will display 6 7...

Page 25: ...cess mode so it is need to set the SSID and Password to allow other device connect to it The default SSID is xxxxx the default password is 12345678 Time Date Press or to change time date then press Se...

Page 26: ...the touch screen or keyboard the timer of Auo Power Off will be cleared and re timed Info The info menu contains all of the product information such as Software Version Serial Number and so on 6 7 2 M...

Page 27: ...rature Unit Temperature Unit have three types to choose C F and K Conversion relationship F 1 8 x C 32 K 273 15 C Temperature Range The temperature measurement ranges have 20 150 C and 0 550 C to choo...

Page 28: ...tory Settings of the Thermal Imager is as follow Item Measurement Measurement Parameters Image System Setting Format Memory No Yes Parameter Center Spot Measurement Hot Spot Measurement Cold Spot Meas...

Page 29: ...Note Images and video files are stored in SD Memory Card Images can easily be read and second analyzed within Thermal Imager PC software 6 8 1 Save Image 1 In desktop press Trigger button freeze an im...

Page 30: ...y ambient temperature humidity reflect temperature infrared compensation distance 6 8 4 Add Analyse Tools Touch the Measurement icon it can add or change the analyse tools in the image point analyse a...

Page 31: ...p4 video capture 1 In desktop press Trigger button and hold for about 2 seconds start video capture with voice 2 To stop video capture press Trigger button again The video saved in the video file 6 10...

Page 32: ...mage analysis mode Which can change the measure parameters analyse tools image mode and color on the image 6 10 2 Play a Video When current file type is video press to play video 6 10 3 View Image Inf...

Page 33: ...ating Instruction for Thermal Imager 6 11 USB Mode Connect USB cable to device popup the menu as follow There are two modes for USB Storage and PC Camera press up or down button to switch mode USB CON...

Page 34: ...the problem persists disconnect the power and contact with the company s technical support department Phenomenon of the fault Thermal imager cannot start Thermal imager shut down No Thermal image Cau...

Page 35: ...earch Thermview on Google Play and install it iOS Search Thermview on Apple Store and install it 8 2 Thermview Function 8 2 1 Import Pictures 1 Enable WIFI function on the thermal device 2 Connect the...

Page 36: ...ible picture is fusioned with infrared picture 2 Colorbar Select Click icon to select colorbar There are eight colorbar for you choice 3 Analyse Click icon to analyse the IR pictures There are three a...

Page 37: ...mal Imager 4 Save and Exit Click to save and return to the main page of the APP 8 2 3 Report and Share 1 Report Click icon to report as a pdf file 2 Share Click icon to share the Infrared picture with...

Page 38: ...Net Framework 2 0 till it finishes If your system already have installed Net Framework 2 0 then no need to install again 9 2 IRMeter Install You can insert your installation CD to install directly if...

Page 39: ......

Page 40: ...Rev 210527 Operating Instruction for Thermal Imager...

Reviews: