TSR-UL-0061-1.3
CHAPTER 1 :
Introduction
4
1.1.4 Part ratings
emerald has been tested for operation within the ranges specified in the table below.
Part
Rating
emerald terminal
0º to 49ºC (32º to 120ºF) flame retardant polycarbonate,
Humidity 5% to 95% non-condensing
DC power (unit only)
12V nominal (11.75V – 12.25V) @ 500mA peak. Shall be powered by an
external UL294 or UL603 listed power-limited power supply with
appropriate ratings and external power on indicator.
Inputs
Four supervised analog inputs - voltage supplied
Comms to system host
10/100 Base-T, TCP/IP, CAT5/5e/6, RJ45 connector
Dry contact relay outputs
0 - 30VDC @ 2A each
a
a. When powered from an external source, the current per load is limited to 2A by the relay, but
the total current drawn is also limited by the capability of the external power supply.
Wet contact relay outputs
11.3-12VDC @ 1.3A combined between both outputs
b
b. If the power to drive the relay loads are sourced from the internal supply, the total current
required from the external supply is Relay 1 LOAD + Relay 2 LOAD + 0.5A.
Ethernet communications
10/100BaseT Ethernet - RJ-45 connector
Memory
128MB RAM, 256MB NAND Flash supporting up to 250,000 cardholder
records and 50,000 transactions off-line)
Table 3: Table of part ratings
Summary of Contents for emerald TS100
Page 1: ...TSR UL 0061 1 3 emerald Quick Start Installation Guide...
Page 4: ...TSR UL 0061 1 3 This page is intentionally blank...
Page 14: ...TSR UL 0061 1 3 CHAPTER 1 Introduction 8...
Page 34: ...TSR UL 0061 1 3 26 This page is intentionally blank...
Page 38: ...TSR UL 0061 1 3 30 This page is intentionally blank...
Page 46: ...CEM Systems 195 Airport Road West Belfast BT3 9ED United Kingdom Tel 44 0 2890 456767...