background image

emerald Quick Installation Guide

7

1.3  Hardware Installation Process

Figure 5 

Hardware installation flow chart

Summary of Contents for emerald TS100

Page 1: ...TSR UL 0061 1 3 emerald Quick Start Installation Guide...

Page 2: ...e fullest extent of the law including pursuit of criminal prosecution wherever necessary All trademarks not owned by Tyco Security Products are the property of their respective owners and are used wit...

Page 3: ...nte Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas p...

Page 4: ...TSR UL 0061 1 3 This page is intentionally blank...

Page 5: ...the terminal s back casing 9 3 Wiring the Terminal 11 3 1 Cabling requirements 11 3 1 1 Ethernet host 11 3 2 The Main Board 12 3 3 The Input Output Board 13 3 4 Wiring locks 14 3 4 1 Wiring a voltage...

Page 6: ...the terminal IP address gateway and subnet mask 24 4 2 2 Network routing advanced users 25 4 2 3 Testing the connection with the AC2000 server 25 5 Using the Terminal 27 5 1 Presenting your card 28 6...

Page 7: ...Used as part of the AC2000 system emerald controls access to restricted areas while giving the user a wide choice of information tools and applications at the door The AC2000 software suite has not be...

Page 8: ...typical read range for the integrated 13 56MHz read head is 3 5cm 1 2 2 Supported card technologies The emerald multi smart card reader supports the following card technologies CEM DESFire MIFARE CSN...

Page 9: ...ystem and is outlined in Table 2 1 1 3 Terminal dimensions Figure 2 Illustration of emerald including dimensions Dimensions of the emerald terminal Length 157mm 6 2 Width 109mm 4 3 Depth bottom 49mm 1...

Page 10: ...stem host 10 100 Base T TCP IP CAT5 5e 6 RJ45 connector Dry contact relay outputs 0 30VDC 2A eacha a When powered from an external source the current per load is limited to 2A by the relay but the tot...

Page 11: ...ts Back casing I O board Ribbon cable with ferrite Front casing Front board Back assembly Front assembly RJ 45 10 100 jack Front board CPU board Chassis grounding post Figure 3 Illustration of the key...

Page 12: ...TER 1 Introduction 6 1 2 Simplified AC2000 Network Topology Figure 4 Basic illustration of a typical AC2000 network including emerald configurations Important The emerald terminal is only available as...

Page 13: ...emerald Quick Installation Guide 7 1 3 Hardware Installation Process Figure 5 Hardware installation flow chart...

Page 14: ...TSR UL 0061 1 3 CHAPTER 1 Introduction 8...

Page 15: ...back box mounted vertically 75mm 3 VESA mount 2 1 Preparing for mounting Care must be taken with the internal components when disassembling the terminal 2 1 1 Recommended tools 3 mm 0 1 slot screwdri...

Page 16: ...ition a 5 mm 0 2 flat head screwdriver under the panel and slide it along the length to release it Note A factory shipped terminal does not have the panels fitted 2 Set the terminal on a stable level...

Page 17: ...O board 1 Remove the four screws and spacers using a Phillips star head screwdriver 2 Lift the I O board away from the mountings 3 Drill the back outer casing as required for cable access and back box...

Page 18: ...ill hole dimensions Mounting hole Description A Generic positions for wall mounting These holes are accessible when the I O board is in place B UK single back box C US Single back gang electrical junc...

Page 19: ...he cable is subject to movement or vibration stranded Ethernet cable and appropriate connectors should be used Purpose Recommended Cable Connector Max Length External 12V supply Belden 8760 18AWG two...

Page 20: ...ator LED PoE has not been evaluated by UL D RJ 45 connector Used for ethernet communications and also for Power over Ethernet when being used E Chassis grounding post Chassis ground to be tied to eart...

Page 21: ...rom this circuitry to power attached door furniture D Output 0 Lock output either 12V provided by the terminal or 12 24V provided externally via the relay and a UL294 or UL603 listed power supply E Ri...

Page 22: ...nt The output state switch must be configured for the correct type of supply as described in this section 3 4 1 Wiring a voltage provided lock internal power Only 12V locks can be wired to be powered...

Page 23: ...e lock The fail secure configuration means that in the event of a power loss to the terminal the lock will remain secure A lock that requires power to open such as a shear lock must be used Figure 12...

Page 24: ...separate 12 24V DC UL294 or UL603 listed power supply must be used to provide power for any locks or other door furniture attached to the output Internal power When the switch is set to INT the lock...

Page 25: ...17 3 5 Terminal with Request to Exit Switch Figure 14 emerald master terminal with REX wiring diagram Note Terminals J1 and J11 have no functional impact use on this product version and are not suppo...

Page 26: ...eration of the inputs on the terminal when configured with a Request to Exit switch Note Inputs are not for use as part of a burglar alarm system Inputs not in use The door position input 0 must be sh...

Page 27: ...emerald Quick Installation Guide 19 3 7 Terminal with Third Party Wiegand Read Head Figure 15 emerald master terminal with Wiegand read head wiring...

Page 28: ...onfigured with a third party Wiegand read head Note Inputs are not for use as part of a burglar alarm system Inputs not in use The door position input 0 must be shorted out between the IP0 and GND pin...

Page 29: ...d to monitor the input 3 9 1 Wiring the resistor network A B Figure 16 Illustration of the resistor network for four state tamper detection on inputs Important It is imperative that the tamper resisto...

Page 30: ...places with the screws 4 Attach the side panels to the terminal Note If the terminal needs to be open after installation the side panels can be removed by inserting a 5 mm 0 2 flat head screwdriver in...

Page 31: ...dicator represents a different aspect of the network connectivity The presence or absence of a block indicates whether or not the connection is good Figure 18 The network status indicator Network stat...

Page 32: ...server this passcode will be changed to 67670000 The final four digits of this PIN are configurable using the AC2000 software 4 2 1 Setting the terminal IP address gateway and subnet mask 1 From the C...

Page 33: ...on Menu press Tests Network tests 2 Press the Ping address field below Ping any Figure 22 Testing the connection with the AC2000 server 3 Type the IP address of the AC2000 server CDC RTC and press OK...

Page 34: ...TSR UL 0061 1 3 26 This page is intentionally blank...

Page 35: ...the door You can see which mode the terminal is in by the Home screen display Door mode The door enables access to all valid cardholders after their card is swiped Free access mode In Free access mod...

Page 36: ...rald terminal s LED status indicator changes colour and the appropriate response screen is displayed The response screens are described in Table 3 below Screen Message Description Access granted LED G...

Page 37: ...granted as your card has expired Lost Stolen Card LED Flashing red Access is not granted as your card has been reported as lost or stolen Wrong Time LED Red Access is not granted as you are attempting...

Page 38: ...TSR UL 0061 1 3 30 This page is intentionally blank...

Page 39: ...Interface to access diagnostic and testing functionality 6 1 Navigating the Menus Sub menus on the emerald terminal are accessed by touching the menu option to expand Menus are expanded and closed by...

Page 40: ...767000 Note See Accessing the System Configuration Menu on page 24 for more details on passcodes Figure 24 Accessing the configuration menu The system configuration menu has three sub menus each of wh...

Page 41: ...d cardholder database View information about the terminal device configuration View the status of terminal connections including comms and tamper Info Description CEM address The CEM reader address of...

Page 42: ...Info Description CEM address The CEM reader address of the terminal Coldstart count Record of the number of times the terminal has been coldstarted Last coldstarted Date and time of the terminal s las...

Page 43: ...as door position lock sense etc Main reader Indicates the status of the emerald master terminal Door interface Indicates whether a door interface unit is currently connected to the emerald terminal T...

Page 44: ...a 4 state configuration as described in section 3 9 1 on page 21 all four input state tests can be administered Open Indicates a tamper cut fault condition Opened The input is open Closed The input is...

Page 45: ...her provided IP address Figure 29 Terminal network tests There are two possible responses for the ping utilities Red No response received Green Response received 6 3 Maintenance There are no required...

Page 46: ...CEM Systems 195 Airport Road West Belfast BT3 9ED United Kingdom Tel 44 0 2890 456767...