2.3
CelloTrack Connector
The CelloTrack 6-pin connector is protected by a plastic cover, providing IP67 compliance.
The following illustration shows the CelloTrack unit with the rubber cover removed.
The connector pin out is as follows:
Pin 1 – VCC
Pin 2 – Ground (GND)
Pin 3 – General Purpose I/O 1 (GP1)
Pin 4 – General Purpose I/O 2 (GP2)
Pin 5 – TXD
Pin 6 – RXD
------------------------------------------------------------------------------------------------
NOTE:
Removing the connector cover revokes the unit’s IP67 compliance. It is the
customer’s responsibility to provide proper sealing if the connector cover is removed.
------------------------------------------------------------------------------------------------
Pin 1