3.
Connect the charger to the CelloTrack connector. If the battery is not fully charged the
charger LED color is red.
4.
Wait till the LED on the charger changes its color from red to green.
5.
Disconnect the CelloTrack unit from the charger and only then you may remove the
charger from the electricity outlet.
6.
Reassemble the connector cover. Fasten it tight to ensure IP67 compatibility.
------------------------------------------------------------------------------------------------
CAUTION:
To prevent damage to the unit, charging the battery must take place only
when the battery is connected.
------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------
NOTE:
The charging of a fully drained battery may take up to 24 hours.
------------------------------------------------------------------------------------------------
3.4
Initial Setup for the CelloTrack Power
To setup the CelloTrack Power unit, perform the following steps:
------------------------------------------------------------------------------------------------
NOTE:
The unit set up should be conducted under lab conditions.
------------------------------------------------------------------------------------------------
1.
Loosen the eight screws and remove the back cover of the CelloTrack unit.
------------------------------------------------------------------------------------------------
NOTE:
Make sure the SIM card is not PIN protected.
------------------------------------------------------------------------------------------------
2.
Prepare the SIM card. If the SIM is PIN protected, insert it into a cell phone and
disable the PIN code.
3.
Gently slide the SIM card into the SIM holder on top of the modem.
4.
Verify that the rubber seal (O-ring) is securely in place.
5.
Close the unit and make sure not to damage the battery wires while closing it.
6.
Insert the eight screws. First, tighten the central screws and then the other screws.
Tighten screws to a torque of 4 kgf-cm (kilogram force per centimeter) which is
approximately 0.4 Nm (Newton per Meter).
3.5
Enable Cradle Tamper Switch
In order to detect removal of the cradle from a surface, the cradle tamper switch should
be enabled.
To enable the cradle tamper switch, remove its screw and the plastic bar which hold the
cradle tamper switch in its non-active position.