3.12
CelloTrack Activation and Deactivation
3.12.1
Activation
1.
After mounting and properly placing your CelloTrack device in the cradle, you may
switch your unit on to begin tracking.
2.
Make sure the unit is correctly and securely mounted on the cradle and the Tamper
Switch is pressed.
3.
Press the Front Button (FB) and hold it. The SYS LED (left LED in the picture below)
should glow for about 3 seconds. Stop pressing the FB only after the SYS LED ceases
glowing.
4.
After several seconds the GSM LED (right LED) should blink (once) and then begins a
slow flash, indicating that your device is ON and working properly.
5.
Your unit is now functioning and will begin reporting as requested.
If the Tamper Switch is not pressed (the unit is out of the cradle or if Cradle Tamper
Switch is enabled the cradle is removed from the asset surface) and the FB is pressed the
SYS LED (left LED) begins to blink (1 sec on/1 sec off) which means that the activation
has failed.
3.12.2
Deactivation
You can also deactivate the unit in order to store it for a long period without
disassembling the battery.
To deactivate the unit, perform the following steps:
1.
Dismount the unit from the cradle. Make sure the tamper switch is not pressed.
2.
Press the Front Button and hold it. The SYS LED (left LED) should blink for 1 second.
3.
After the SYS LED ceases glowing, stop pressing the FB.
4.
Both LEDs are now off, indicating that the unit is deactivated.