Remote Control / Display Instructions 

 

 

 

Digital Display

 

The temperature is displayed on the control in red. 
Press “Power On/Off” to turn on and off. 
When the “Compressor On” indicator light is on, the Compressor is 
running.  
When the “Fan On” indicator light is on, the Fan is running. 
The cooling system is programmed with a Startup Delay to protect its 
internal components.  Upon installation, we provide instructions for the 
installer to change the delay to 30 minutes.

 

Quick Chill 
Button

 

 Button 

Icon

 

To activate the “Quick Chill” mode, press the “Up” button for 3 seconds

 

To deactivate “Quick Chill”, press the “Up” button for three seconds 
again 
The “Quick Chill” indicator (Row 3) light will turn on when the cooling unit 
is in “Quick Chill” mode,  
In the “Quick Chill” mode, the cooling unit will run continuously for 6 hours 
(or until the unit reaches set point.).  This mode is useful after loading 
“warm” bottles in the cabinet.

 

Auto Defrost 
Mode

 

The cooling unit has a factory default defrost cycle that initiates every 
16 hours for 20 minutes.  When the cooling unit is in auto-defrost mode, 
the “Defrost” Indicator light (Top row) will turn on, and the evaporator 
fan will run.

 

Manual Defrost

 

 

 

Hold the defrost button in for 3 seconds to initiate a manual defrost.   The 
“Defrost” Indicator light (Top row) will turn on for a 20 minute defrost 
cycle.

 

Light

 

 

The light button function is disabled, however pressing it will turn on/off 
the light indicator on the display (2nd row).

 

Energy Saver

 

 

The remote display is not configured with an Energy Saver mode.   The 
set point can be raised manually for periods where energy savings is 
desired.

 

Summary of Contents for 4000Shwc

Page 1: ...V10 19 ControltheElements SplitWaterCooled RefrigerationSystems Owner sManual...

Page 2: ...ellarPro Cooling Systems 1445 N McDowell Blvd Petaluma CA 94954 707 794 8000 Email info cellarprocoolingsystems com Website www cellarprocoolingsystems com IMPORTANT WARRANTY INFORMATION FOR YOUR SPLI...

Page 3: ...t e n t s I Package Contents 4 II Specifications Cut Sheets and Cellar Construction 5 III Installation Instructions 10 IV Operating Instructions 30 V Troubleshooting 37 VI Limited Warranty 42 VII Warr...

Page 4: ...1 FT DRAIN KNOCKOUT SNAP BUSHING 1 SIGHT GLASS 1 FILTER DRIER 1 BOX 2 DESCRIPTION QTY CONDENSING UNIT 1 4000Shwc 8000Swc BOX 1 DESCRIPTION QTY EVAPORATOR 1 REAR WALL MOUNTING BRACKET 2 WALL MOUNTING S...

Page 5: ...6 x 12 6 x 22 1 incl mounting brackets 42 8 6 4000Shwc 30 4 x 14 4 x 13 2 incl mounting bracket 65 8 6 8000Swc 46 4 x 14 4 x 13 2 incl mounting bracket 85 12 3 Condensing unit Indoor Model Dimensions...

Page 6: ...6 V10 19 Evaporator Cut Sheets...

Page 7: ...7 V10 19 Condensing Unit Cut Sheets...

Page 8: ...is important that all walls joints doors and windows electrical outlets and or switches pipes vents and light fixtures be sealed to prevent air and moisture from entering the cellar If there is a leak...

Page 9: ...re stratification inside the cellar the space in front of the cold air discharge should be clear of any obstructions including wine bottles wine racks etc Ducting Cold air exhaust and return from the...

Page 10: ...0 F The area must have suitable ventilation to maintain an ambient temperature of 110 F or less If the area does not have adequate ventilation a vent fan should be added to supply fresh air to the spa...

Page 11: ...11 V10 19 4000Swc Side mounting brackets are provided for mounting the evaporator flush to a wall inside the cellar Optional top and bottom brackets non load bearing are available upon request...

Page 12: ...ngers are used to mount these split systems First wall brackets are attached to the wall and then the evaporator slides onto the brackets After the evaporator is installed two bottom nuts must be inst...

Page 13: ...gain into an open drain Then fill the trap with water The condensate trap will allow any excess moisture inside the Evaporator to overcome the static pressure and flow out of the drain line Before put...

Page 14: ...8 1004 974 NOTES Option A Dual Power Valve Control Option B Single Power Electronic Control 1 A 15 amp dedicated circuit breaker non GFI is recommended for 4000Swc 4000Shwc systems 2 A 20 amp dedicate...

Page 15: ...vaporator turns off the LLSV closes causing the system to pump down until the low pressure switch shuts off the Condensing unit When the Evaporator turns on the LLSV opens causing the suction pressure...

Page 16: ...16 V10 19 Wiring Diagrams Option A Dual Power Valve Control Models 4000Swc 4000Shwc...

Page 17: ...17 V10 19 Wiring Diagrams Option A Dual Power Valve Control Model 8000Swc...

Page 18: ...d to Evaporator terminal L Connect neutral lead to Evaporator terminal N Connect power ground to grounding lug on Evaporator The Condensing Unit is powered by connecting it to the Evaporator is follow...

Page 19: ...19 V10 19 Wiring Diagram Option B Single Power Electronic Control Models 4000Swc 4000Shwc...

Page 20: ...20 V10 19 Wiring Diagram Option B Single Power Electronic Control Models 8000Swc...

Page 21: ...ry installed evaporator suction access valve 8 Insulated suction line refrigeration piping refer to Line Sizing Chart below 9 Suction connection location 9a 4000Swc 9b 8000Swc 10 Condensing unit liqui...

Page 22: ...ances 3 Use only dehydrated refrigeration service tubing and refrigeration grade fittings 4 Install refrigeration piping in accordance with local codes and ASHRAE guidelines Suction Line Size by Lengt...

Page 23: ...ondensing unit a suction trap must be installed at the evaporator and an inverted trap must be installed at the condensing unit for proper oil return as follows 3 When the evaporator is located above...

Page 24: ...stem to avoid rounding the valve stem edges The valve is closed with the stem turned in fully clockwise open with the stem turned out fully counterclockwise The access ports are back seating meaning t...

Page 25: ...bient or if the system has been sitting idle for more than 24 hours it is critical to warm the bottom shell of the compressor above the ambient temperature for 30 minutes to drive excess refrigerant o...

Page 26: ...e condensing unit dual pressure control is configured with the high pressure tap factory installed The low pressure tap is capped and not connectedinstalled on an access valve on the compressor proces...

Page 27: ...ructions to airflow Observe system pressures and temperatures during charging and initial operation and keep note of them as they will be required for the Service and Support Data Sheet which initiate...

Page 28: ...lent feet for fittings losses System R 134a Charge Guidelines System Charge lbs by Split Water Cooled System Model Ducting for the Evaporator 4000Swc Models Cold air exhaust and return from the evapor...

Page 29: ...llar Without proper insulation and an airtight environment the cooling unit effectively will become a de humidifier and potentially will produce buckets of water The condensing unit cannot be exposed...

Page 30: ...eratures for white and sparkling wines CellarPro cooling units must be used stored moved and or shipped in the upright position Be careful when turning the unit on its side The unit NEVER should be tu...

Page 31: ...itch Low Med High The cooling unit fans operate on 3 speed settings Low Medium and High For optimum sound and energy efficiency select the lowest fan speed that will maintain the desired cellar temper...

Page 32: ...f Press Power On Off to turn on and off When the Compressor On indicator light is on the Compressor is running When the Fan On indicator light is on the Fan is running The cooling system is programmed...

Page 33: ...Differential of 4 F This means that the cooling unit will turn on when the display rises above 62 F 58 F 4 F and turn off when the display falls below 58 F In this example the average temperature insi...

Page 34: ...e Differential is unchanged Quick Chill Button To activate the Quick Chill mode press the Up Quick Chill button for three seconds To deactivate Quick Chill press Quick Chill button for three seconds a...

Page 35: ...ling unit is in Quick Chill mode In the Quick Chill mode the cooling unit will run continuously for 6 hours or until the unit reaches set point This mode is useful after loading warm bottles in the ca...

Page 36: ...y preset ENERGY SAVINGS MODE DIFFERENTIAL The factory preset for this setting is 4 This setting controls the Temperature Differential for the Energy Savings Mode The recommended range for this setting...

Page 37: ...nit 2 Raise the Minimum Set Point on the cooling unit Cooling Unit Is Dripping The cooling unit is designed to remove excess moisture from inside the cellar which collects in the drip pan of the cooli...

Page 38: ...laced Consult factory No power to compressor Power supply to Condensing Unit interrupted Restore power Check for loose wires and reconnect Low pressure switch is open On Valve control systems make sur...

Page 39: ...Fan obstructed With power to unit disconnected check the rotation of the blower fan If fan does not spin freely inspect for and remove obstructions If no obstructions are found the fan may need to be...

Page 40: ...iagram for Electronic or Valve controlled system trace wiring and correct If a Valve control system the low pressure switch may have failed closed Check switch and replace if necessary No airflow See...

Page 41: ...ged in and or turned on The control panel also will flash a code for each alarm as follows Alarm What it means What to do P1 Probe 1 which senses the temperature inside the cellar and controls the on...

Page 42: ...reinstalling the cooling unit from the wine cellar The limited warranty applies only to cooling units purchased from the factory or an authorized dealer Damage caused by others or by any cause beyond...

Page 43: ...t Charge Through Check One ____ Suction Access Valve ___ Liquid Access Valve Operational Data Take the following measurements during a normal refrigeration cycle once the cellar has pulled down to the...

Reviews: