www.cellarcool.com | Page 11
Remove 30 8-18x3/8” Phillips Pan Head
screws followed by sliding the cover off of the
evaporator unit.
Note: Do not remove the two screws on the
rear of the evaporator unit securing the End
Cap.
Drill two 5/32” pilot holes in the line
intersections (make sure they are
16” on center). Screw in one of the
provided 1 3/4” Hex Head screws in
the right hole.
Install the evaporator unit by aligning
the center vertical key hole with the
screw on the wall. Place unit on the
screw and tighten down.
HORIZONTAL MOUNT INSTALLATION
Note: The screws should
be installed with about
1/16” between the wall
and screw head