background image

Assembly and installation 

 

 

2020/7/V1.0 

33 | 69  

Manual-No.: 10001_hdb_en 

 

 

 

5.3 

Mounting distances 

 

 

Abb. 23. 

Mounting distances 

 

SPMB-16DIO 

SPMB-04AIO 

70 mm 

70 mm 

>20 mm 

>20 mm 

 

 

NOTE 

 

Ensure sufficient space for easy module replacement and observe the 
bending radii of the cables! 

 

 

 

Summary of Contents for Spider67

Page 1: ...Manual Spider67 Mobile series IoT Gateway...

Page 2: ...H also in case of applications for industrial property rights We reserve all rights of disposal such as the right to copy and pass on the material The frontpage shows an example configuration The deli...

Page 3: ...ible gateway mobile version SPMB 16DIO 002 Digital 16 way extensible gateway WiFi version SPMB 16DIO 003 Digital 16 way extensible gateway mobile WiFi version SPMB 16DIO 012 Current analog input 4 way...

Page 4: ...to the unit 11 3 General description 15 3 1 Product characteristics 16 3 2 Product series 16 3 3 Scope of delivery Spider67 Mobile SPMB 16DIO 16 3 4 Scope of delivery Spider67 Mobile SPMB 04AIO 16 3...

Page 5: ...gin 43 7 3 Device Management 49 7 4 Cloud Logical control 53 8 Maintenance cleaning service 56 8 1 Maintenance 56 8 2 Cleaning 56 8 3 Service 56 9 Transportation storage disposal 57 9 1 Transportation...

Page 6: ...of this device It contains safety instructions that you must follow as well as information necessary for the trouble free operation of the device Ensure that all persons who carry out activities on t...

Page 7: ...ble 1 You have read and understood the documentation 2 Only then you will put the unit into operation 1 4 Explanation of symbols and spelling For safe working on and with the product Elco instructions...

Page 8: ...n hints 1 4 2 Used warning and command signs Warning sign General warning sign Warning of electrical voltage Mandatory sign General mandatory sign Refer to the instruction for use Ground before use Ot...

Page 9: ...tion In the instructions we show you how to proceed to achieve a goal Action goal Tools and requirements optional Action step Action step Action step Result optional Action goal observe sequence Tools...

Page 10: ...Spain Sweden Switzerland United Kingdom In countries not listed above please consult Elco Industrie Automation GmbH before commissioning 2 2 Unintended use Do not use the device outside the areas desc...

Page 11: ...ar intervals Inform external persons in detail about the dangers 2 5 Danger due to electrical voltage During operation certain parts of the equipment may be under dangerous voltage Observe the warning...

Page 12: ...Safety instructions 2020 7 V1 0 12 68 Manual No 10001_hdb_en 2 7 EU Declaration of Conformity...

Page 13: ...Safety instructions 2020 7 V1 0 13 69 Manual No 10001_hdb_en...

Page 14: ...Safety instructions 2020 7 V1 0 14 68 Manual No 10001_hdb_en...

Page 15: ...Gateways have the following features Basic definition and configuration of I O channels Flexible adaption of I O control logic in the cloud Acquisition upload and processing of digital and analog sig...

Page 16: ...b also offers several open API interface services A detailed description can be found in the IoTHub user manual 3 2 Product series Pos I O Article name Description 1 DIO SPMB 16DIO 001 Digital expanda...

Page 17: ...ion and is individual 3 5 3 Elco IoTHub All products of the Spider67 Mobile series are factory connected to Elco IoTHub The IoTHub is a powerful cloud environment that can be flexibly extended and con...

Page 18: ...he module as standard ex works and can be activated A separate mobile phone contract with Elco must be concluded for this purpose M12 cables For the intended use of the Spider67 Mobile the terminating...

Page 19: ...d in the field to collect sensor data The sensor data is transmitted to the IoTHub via mobile radio and stored and processed there From the IoTHub Elco provides a standard web interface for configurin...

Page 20: ...a 6 8x I O ports P0 P7 for 16 inputs or outputs 2 Mobile phone antenna 7 Power supply M12 male A coded 3 Status display for the gateway 8 I O port for forwarding the signals to the expansion module M1...

Page 21: ...8 DI 8 DO application 8 inputs 8 outputs Free configuration ATTENTION Device defect to excessive total current When connecting the expansion modules observe the maximum total current of 4 A and power...

Page 22: ...LED 2 Module and output 24 V DC 3 bridged Module and output 24 V DC 4 Module and output GND 5 PE 4 3 1 4 Internal system connection Link siehe auch Fehler Verweisquelle konnte nicht gefunden werden 8...

Page 23: ...ules ATTENTION Device defect due to excessive total current When connecting the expansion modules observe the maximum total current of 4 A and power limitation per channel 4 3 2 1 Example 1 I O expans...

Page 24: ...pider67 Mobile DIO 4 3 2 3 Example 3 I O expansion with 2 analog und 2 digital expansion modules Abb 9 I O expansion with 2 analog und 2 digital expansion modules 4 3 2 4 Example 4 I O expansion with...

Page 25: ...ies Abb 11 Multi channel LED display 4 3 4 I O display left and right of the ports Abb 12 LED display per port 4 3 5 eSIM card The Spider67 Mobile is delivered ex works in Europe with an integrated eS...

Page 26: ...ends on the number of final extensions By default the gateway already occupies the first two places Thus the first upper port 0 3 is module 0 and the lower 4 ports 4 7 are module 1 Here one digital mo...

Page 27: ...d as Module_0 The ports P4 P7 are defined as Module_1 see the following figure The following extended I O modules are numbered sequentially with Module_2 Module_3 etc Abb 14 Port and module numbering...

Page 28: ...ort for 4 inputs M12 male plug B coded 2 Power supply M12 male plug A coded 5 2x mounting holes 3 I O display for each port 4 4 1 Connections 4 4 1 1 I O connections siehe 0 4 The SPMB 04AIO Gateways...

Page 29: ...e PIN indicator 45 counterclockwise to match the gateway installation diagram Abb 17 Connection for power supply M12 female A coded Pin no Pin assignment Information display 1 Module and output 24 V D...

Page 30: ...display Abb 19 LED display for each port 4 4 3 Expansion of the SPMB 04AIO series NOTE The module is not expandable Abb 20 P0 P3 ports of the SPMB 4AIO gateway module_0 4 4 4 SPMB 04AIO series channe...

Page 31: ...Assembly and installation 2020 7 V1 0 31 69 Manual No 10001_hdb_en 5 ASSEMBLY AND INSTALLATION 5 1 Dimensions SPMB 16DIO Abb 21 Dimensions SPMB 16DIO in mm...

Page 32: ...Assembly and installation 2020 7 V1 0 32 68 Manual No 10001_hdb_en 5 2 Dimensions SPMB 04AIO Abb 22 Dimensions SPMB 04AIO in mm...

Page 33: ...0 33 69 Manual No 10001_hdb_en 5 3 Mounting distances Abb 23 Mounting distances SPMB 16DIO SPMB 04AIO A 70 mm A 70 mm B 20 mm B 20 mm NOTE Ensure sufficient space for easy module replacement and obse...

Page 34: ...mounting distances see chapter Fehler Verweisquelle konnte nicht gefunden werden Fehler Verweisquelle konnte nicht gefunden werden that connecting cables cannot be torn off that the module cannot be u...

Page 35: ...d sockets The protection class IP67 is only guaranteed if all connections are tightly sealed Seal unused plugs and sockets with screw plugs or caps 5 6 1 Power supply M12 socket ATTENION Damage to the...

Page 36: ...12 field wiring connector B coded Torque spanner M12 Torque 0 8 Nm Screw the M12 plug firmly onto the socket Connecting antennas Connecting antennas to SMA socket SMA torques spanner Torque 1 Nm Screw...

Page 37: ...arge 6 1 Initial start up Spider67 Mobile The SPMB 16DIO and 04AIO products support WLAN IEEE 802 11 b g n 2 4 GHz The WLAN function of the SPMB 16DIO gateways supports the AP client Access data You w...

Page 38: ...m App Start Spider67 m App Display start screen Tap on the 3 dots in the upper right corner About is displayed Tap on About Display of the version Tap on Check updates The app downloads updates Tap o...

Page 39: ...can rename the Spider Tap on the red dustbin The current data is deleted Settings of the Spider67 Wi Fi 4G Select Wi Fi The Spider67 connects to Wi Fi Select 4G The Spider67 connects to LTE Select on...

Page 40: ...AN Red Error not connected MOD Module status Green fast flashing 3Hz Initialize module Green slow flashing 1Hz Module is updating firmware Signal LTE module Green Signal very good 100 80 signal streng...

Page 41: ...s Function B A P0 P7 Green Signal high Off Signal low Red Error voltage too high low or short circuit 6 3 SPMB 04AIO diagnostics INFO The LED display is identical in all modules of the SPMB 04AIO seri...

Page 42: ...100 80 signal strength Orange Device connected bud bad connection to server or WLAN Red Error not connected MOD Module status Green fast flashing 3Hz Initialize module Green slow blinking 1Hz Module...

Page 43: ...eries will be adapted gradually Elco will update the relevant platform functions and descriptions according to the product delivery schedule Elco has the final design right 7 1 Architecture of the sta...

Page 44: ...systems store or record login information Elco recommends using browsers that support the Google Chrome kernel This ensures the highest possible level of user security Login Enter the address of the...

Page 45: ...e user management we distinguish between users User groups Group and roles Roles The Admin can create and manage any number of users These users do not have any permissions or properties Abb 33 User m...

Page 46: ...thermore devices agents and workflows can also be directly assigned to only one role Abb 35 Assigning properties to a role In order to use now the defined properties of the role with the users a group...

Page 47: ...1 0 47 69 Manual No 10001_hdb_en Abb 37 Displaying all members of the group The Members button can now be used to assign the required members to the group Abb 38 Assigning members to the group Abb 39...

Page 48: ...Application platform 2020 7 V1 0 48 68 Manual No 10001_hdb_en The Groups button can now be used to assign the created roles to the group The members of this group now have these properties...

Page 49: ...d and configured by the IoTHub via the agent implemented in the firmware This makes it much easier for the user to install the device As soon as the Spider67 Mobile connects to the cloud its digital t...

Page 50: ...ing steps The device is switched on and runs stable 3 Perform the steps of the app installation see chapter Fehler Verweisquelle konnte nicht gefunden werden Fehler Verweisquelle konnte nicht gefunden...

Page 51: ...f the Gateway Accessing the function Menu Things Sensor Values After adding the Spider67 Mobile the user can now customize and configure the inputs outputs and expansion modules as desired Abb 44 Defi...

Page 52: ...tion to the real inputs and outputs of the radio system there is now a virtual extension module at the end of the bus system Depending on how many extension modules you use in the system the virtual m...

Page 53: ...nputs and outputs of the devices on the management platform Thus you fulfill the relevant requirements for simple logical control The current version of the logic is based on two different functions o...

Page 54: ...ind the submenu item Logic image Here you can save the logic to the device Abb 46 Implementation local logic The template to be used is structured as follows Value Input Sensor Logic Status Output The...

Page 55: ...gateway is divided into two individual sub modules in the software Thus the ports P0 P3 belong to module 0 and the ports 4 7 to module 1 Abb 49 Port and module numbering INFO When using the local log...

Page 56: ...nd service work of the machine and during configuration the device can remain connected to SELV or PELV circuits 8 1 Maintenance The modules are maintenance free 8 2 Cleaning Clean the module only wit...

Page 57: ...rials carefully The separated materials are sent for recycling Disposal in the country of use Observe the regulations in the country of use for the disposal of electronic devices Dispose of unusable d...

Page 58: ...ternal system bus M12 socket B coded I O channel Signal connection 2 states per port 16 ports in total Digital input Logic voltage low level 0 V 1 2 V Logic voltage high level 3 5 V 30 V Input current...

Page 59: ...W PCS1900 E1 0 4W UMTS power UMTS power class WCDMA 3 0 25W LTE power LTE power class 3 0 25W Tabelle 4 Mobile radio interface Radio interface Designation Value WLAN modules Security WEP WPA PSK WPA2...

Page 60: ...ange Operation 25 70 Storage 35 85 Humidity Humidity during operation and storage 0 95 relative humidity without condensation Protection Protection class to DIN EN 60529 IP67 Shock and vibration Compl...

Page 61: ...gnal 0 2 FSR Resolution 16 bit Impedance 120 Voltage signal 0 1 FSR Impedance 1 K Tabelle 10 Electrical data Radio interface Designation Value WLAN modules WLAN IEEE 802 11 b g n 2 4 GHz Security WEP...

Page 62: ...ge Operation 25 70 Storage 35 85 Humidity Humidity during operation and storag 0 95 relative humidity without condensation Protection Protection class to DIN EN 60529 IP67 Shock and vibration Complies...

Page 63: ...parts 11 2 Spare parts 11 2 1 Mobile radio antenna for SPMB 16DIO series Article name Abbrevation Short description SPMB ANT01 030 SPMB Spider67 Mobile ANT Antenna 01 Antenna type LTE 03 Cable length...

Page 64: ...4AIO Serie Article name Abbrevation Short description SPMB ANT02 030 SPMB Spider67 Mobile ANT Antenna 01 Antenna type WLAN 03 Cable length 3 m 0 Magnetic base antenna Number Dimensions Drawing 1 3000...

Page 65: ...0A 001 Analog extension module Spider67 3AI current mode 0 20mA 4 20mA 20mA 3xM12 2xM12 B coded SPDB 0300A 002 Analog extension module Spider67 3AI voltage mode 0 20mA 4 20mA 20mA 3xM12 2xM12 B coded...

Page 66: ...ctronic Equipment RoHS EU Richtlinie 2012 19 EU Waste Electrical and Electronic Equipment Directive WEEE Electrical and Electronic Equipment Waste Directive EU Richtlinie 2014 53 EU Radio and telecomm...

Page 67: ...m SMA connection Sub miniature A connection for mobile radio antennas and antenna cables SSID Service Set Identifier SSID TCP IP Transmission Control Protocol Internet Protocol TCP IP is a communicati...

Page 68: ...Notes 2020 7 V1 0 68 68 Manual No 10001_hdb_en 12 NOTES...