Optoisolation
~3kV - between signal lines RS-485/RS-422 (RS1) and RS-485/RS-422 (RS2)
Electromagnetic compatibility
Resistance to disruptions according to the standard PN-EN 55024.
Emission of disruptions according to the standard PN-EN 55022.
Safety requiring
According to the PN-EN60950 norm.
Environment
Commercial and light industrial.
Environmental Parameters
Operating temperature
-30 ÷ 60°C
Humidity
5 ÷ 95% - non-condensing
Storage temperature
-40 ÷ 70°C
Casing
Dimensions
53 x 90 x 62 mm
Material
Noryl UL. 94 V-O
Degree of casing protection
IP40
Degree of terminal protection
IP20
Weight
0,10 kg
According to standards
DIN EN50022, DIN EN43880
Location during work
Free
Mounting
Rail mounting according to DIN35 standard / TS35.