7. CHANGES IN THE SOFTWARE
From CPU 2.0 and software 000.007 versions, was added:
- flow data control by the use of DE signal for RS1 (RS485/RS422) & RS2 (RS485/RS422) interfaces. Description of using new option
is in pt. CONFIGURATION BY THE USE OF ADACONFIG,
- converter operating mode
factory default
is set by the use of SW1 micro-switch, see pt. OPERATING MODE
ATTENTION!!!
THE SOFTWARE IN 0.007 VERSION AND UPPER WILL NOT OPERATE WITH THE CONVERTERS WITH CPU 1.0. VERSION.
IN CASE OF UPDATE THE SOFTWARE TO 0.007 VERSION AND UPPER IN THE CONVERTERS WITH CPU 1.0. VERSION
PLEASE CONTACT TO SERVICE.
8. VERSIONS
ADA-4040A -
-
Order example:
Product Symbol:
ADA-4040A-23-3
23
– 3-way galvanic isolation on the level 1kV=,
3
- cover without inlets, plug-in screw terminal block,
Galvanic isolation:
1kV=, 2-way
2
1kV=, 3-way
23
3kV=, 2-way
3
3kV=, 3-way
33
Terminal & Terminal Cover:
Cover without inlets, screw terminal block
1
Cover with inlets, screw terminal block
2
Cover without inlets, plug-in screw terminal block
3
9. SPECIFICATION
TECHNICAL DATA
Transition Parameters
Interface
RS-485/RS-422 (RS1)
RS-485/RS-422 (RS2)
Connector
Screw terminal block - max. Ø 2,5mm
2
Screw terminal block - max. Ø 2,5mm
2
Line length
1200 m (depend on baud rate)
1200 m (depend on baud rate)
Max. number of connected device
32
Baud rates
300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600,
76800, 115200, 230400,
Data format
Data bit: 5, 6, 7, 8,
Parity: None, Odd, Even,
Number of stop bits: 1, 2,
Transmission line
1-pair or 2-pair twisted cable, UTP Nx2x0,5 (24AWG), shield inside large
interferences STP Nx2x0,5 (24AWG)
Transmission type
Asynchronous full duplex, half duplex.
Standards
EIA-485, CCITT V.11
Optical Signalization
•
PWD – green LED power supply,
•
RX - red LED data receiving on RS1 – RS485/RS422 side,
•
TX - yellow LED data transmission via RS1 – RS485/RS422 Bus.
Electrical Parameters
Power requirements
10 – 24 – 30 V DC
Power Cable
Recommended length of power cable – do 3m.
Power
<2W
Protection from reverse power polarization
YES
Galvanic Isolation
1kVDC or 3kVDC - between power circuit and RS-485/RS-422 (RS1,RS2) signal line
13
ADA-4040A