background image

Commercial Electric Heat Limited

           HA

WICK TD9 8SL

No

Part No

Description

No

Date

Revision

Title

Rev

Drawing No.

Date

Drawn by

Scale

L01
1

RCH-W

-008

2

nts

NEB

10.06.98

RCHS/R 4200

Recessed Ceiling Htr

3

Connector 

Block

1

Heating 

Element

4

Blower 

Unit

2

Fan

Motor

6

Schematic diagram

1

2

3

4

B082-01

D002-01

F0015

C001

Heating element

Fan motor

Connector block

Blower unit

2.25kW

2.25kW

4.5kW

1

L

N

LI

L

LII

L

LI

LII

N

L

N

5

Over temp cut outs

6

ODH-RSW

Remote Switch Unit

IMPOR

TANT
:

Any modification to the switching in 

this circuit must ensure that the 

heating elements cannot be energised

without the fan running.

Remote Switch  

ODH-RSW

1

2

Add external cut outs

Change remote switch

11/04

01/07

Heating element incorporates over temperature cut out 

in common terminal.

To reset:

Switch of

f and allow to cool (5 minutes) then restore supply

Heater does not function again until power has been removed

from cut out. 

2

5

Over temp

cut out

Please keep these instructions for future reference                                                                 

P01