FIXING

This heater  is designed for surface installation to any ceiling that can adequately support the unit. 

Fixings are made through the top flat section of the heater body using the 4 No 5mm holes provided. This 

section must be flat on the ceiling as the edges of the cover are designed to fit against the ceiling.

Securely fix the heater and make off the electrical connections taking into account the routing of cables in 

relation to the cover. 

Re fix the cover ensuring the fan outlet is adjacent to the smaller outlet grille.

The unit 

weighs 9kgs.

Remove the front cover of the unit  

Ensure fixings and cables are clear of moving parts and the heater elements.  

The manufacturers reserve the right to change the specification at any time without prior notice  EO&E

ELECTRICAL CONNECTION

 

 

The heater should be installed in accordance with the latest edition of the IEE Requirements for Electrical 

Installation (BS 7671:2001)

Position remote switch unit in suitable location

Select cabling with 4 cores and earth of appropriate size for current and volt drop. 

Pass cable/s through cord grip in top of unit. Leave sufficient length for connection but ensuring cables do 

not foul blower unit. Make off connections to connector block and earth stud in accordance with circuit 

diagram RCH-W-007 ( copy on back page and on top of unit )

If remote switching is not required connect power supply to L and N and link L,LI and LII with 1.5sqmm cable.

Tighten up cord grip. Replace connection cover plate. Replace heater cover.

   

 

   

 

 

 

 

   

 

 

 

 

Position heater in ceiling ( See Fixing )  

Remove side connection cover (2 set screws) 

A means of disconnection having a contact separation of 3mm in all poles should be incorporated..

IMPORTANT : always check to ensure the heating elements cannot be energised without the fan

running.

WARNING THE HEATER MUST BE EARTHED

OVER TEMPERATURE CUT OUT

 

 

 

Should the heater exceed normal operating temperature the over temperature cut out on the heating 

elements will operate.

 

   switch off power to the unit and allow to cool before switching on again. If the problem 

persists consult a suitably qualified person.  

To RESET -

MAINTENANCE  

Isolate the heater and remove any build up of dust etc. every 6 months. Check that the heater has not been 

covered or the airflow restricted in any way.

WARRANTY 

This product is guaranteed, in accordance with our Conditions of Sale, for a period of 12 months from date of 

purchase. We will repair or replace, at our discretion, any part found to be defective. We cannot accept 

responsibility for any consequential liability. 

The warranty will be invalid if the heater has not been installed in accordance with these instructions.

This does not affect your statutory rights.

Reviews: