6

PROGRAMMING CONTINUED… 

 
 
3.6 

There is one last mini-jumper location that has not been addressed yet. 
This jumper is positioned at the time of manufacturing to accommodate 
most telephone environments.  If your telephone line delivers dial tone to 
your phone in one second or less, then you should ignore this section.  If 
you happen to be in a long loop environment, which takes more than one 
second to deliver dial tone on the line, then you will need to locate the 
plastic mini-jumper located at the 

“J2”

 position of the ATD11 board.  The 

“J2” position can be found approximately 1.5” – 1.75” directly below the 
“J1” and “J3” positions and is somewhat by itself.  Position the “J2” 
plastic mini-jumper, so that it bridges the middle and far right copper pins.  
A “3” appears in small white print just right of this position.  Placing the 
jumper there will cause the phone to delay 3 to 4 seconds before dialing.  
This should allow the phone to accommodate those extra long loop 
situations in terms of time to receive dial tone

.   

 

 

3.7

 

Programming is now complete and the telephone is ready for 
testing/operation. 

 
 
 
 
 

4.0 OPERATION 

 

Lift the handset.  After a delay for dial tone, the programmed number will be 
dialed automatically and a normal phone conversation may take place.  The 
volume control button is located on the face of each unit and is marked with the 
loudness symbol.  Each press of the button will increase the volume incrementally 
for a total gain of 18-20dB with an automatic reset on the fourth press of the 
button or upon hang up. 
 
 

 

5.0  RECOMMENDED TOOLS AND TEST EQUIPMENT 

 
  Volt/Ohm 

Meter 

  1/4" 

Nut 

Driver 

 

 

Flat Blade Screw Driver 

 

 

Security Tool, CEECO Part Number 301-064 

 

 
 

Summary of Contents for HOB-331-D-M-IVC

Page 1: ...NE and MODEL SSP 311 D M IVC STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH ATD 11 AUTOMATIC DIALER INTERNAL VOLUME CONTROL BACKGROUND NOISE REDUCTION RECEIVER OPERATED SEALED MAGNETIC HOOKSWITCH Servi...

Page 2: ...llowing information is necessary when calling CEECO for assistance MODEL NUMBER SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED Please keep this information on hand when calling CEECO for technical...

Page 3: ...NERAL DESCRIPTION 4 3 0 PROGRAMMING 5 4 0 OPERATION 6 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 6 PROGRAMMING DIAGRAM 7 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 8 7 0 TESTING 10 8 0 TROUBLESHOO...

Page 4: ...activated by hook switch closure The CEECO Model HOB 331 D M IVC is a Weather Resistant Telephone designed for special purpose applications where a durable telephone must be protected from moderate w...

Page 5: ...digits If the number to be programmed is a local call position the J1 mini jumper on the B position bridging the center and right copper pins 3 4 If a 3 digit area code is to be dialed the J3 mini ju...

Page 6: ...hat it bridges the middle and far right copper pins A 3 appears in small white print just right of this position Placing the jumper there will cause the phone to delay 3 to 4 seconds before dialing Th...

Page 7: ...Issue 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 7 PROGRAMMING DIAGRAM...

Page 8: ...sired Mounting hardware is not included The housings are designed to be mounted on a flat vertical surface Mounting holes are provided on the back of the housings In the case of the HOB model a suitab...

Page 9: ...FIDENTIAL This drawing and all information contained therein is confidential and is the exclusive property of CEECO and may not be copied reproduced or disclosed to anyone in any manner whatsoever or...

Page 10: ...a call is placed to the phone and the handset is lifted there is a one and one half to four second delay depending on the position of J2 Section 3 6 the programmed number is dialed and then a normal...

Page 11: ...E DOESN T DIAL PROGRAMMED NUMBER POSSIBLE CAUSE ATD 11 PRINTED CIRCUIT BOARD PROGRAMMING SWITCH MATRIX SET WRONG JUMPER IN WRONG POSITION PROBLEM RINGER DOES NOT OPERATE POSSIBLE CAUSE RINGER NETWORK...

Page 12: ...Steel ENCLOSURE WPP Model Cast Aluminum HOB Model Painted Steel DIMENSIONS WPP Model 12 5 8 High x 9 1 2 Wide x 8 Deep including door HOB Model 11 1 4 High x 7 1 16 Wide x 5 Deep SSP Model 11 1 4 Hig...

Page 13: ...olume Control Button 1 951 007 W Volume Control PCB with wires 1 401 009 Ringer 1 301 009 Network 1 301 592 Magnetic Hook switch 1 301 018 Modular cord 1 331 003 Stainless steel panel for D and X mode...

Page 14: ...hone Network through a registered jack provided by the telephone company in your area This jack is a modular outlet which you can order from your local telephone company 11 3 NOTIFICATION TO THE TELEP...

Page 15: ...he defective unit This information must be inside the shipping container 12 2 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee Florida 34972 863 357 0798 12 3 NON W...

Page 16: ...d to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse act of God or improp...

Reviews: