CEECO HOB-331-D-M-IVC Service Manual Download Page 10

Issue 4.0 

CEECO 

Communication Equipment & Engineering Company 

PROPRIETARY 

10

7.0 TESTING 

 
 

7.1 

Program the phone according to section 3.0 

 

7.2

 

Lift the handset. Phone waits one and one half to four seconds (depending 
on the  position of J2 per Section 3.6). The programmed number is 
automatically dialed. 

 
 

7.3

 

The transmitter is muted while the phone is dialing. 

 

7.4

 

Incoming calls are not recommended but if a call is placed to the phone 
and the handset is lifted there is a one and one half to four second delay 
(depending on the position of J2. Section 3.6), the programmed number is 
dialed, and then a normal phone conversation can take place. 

 
 

8.0 TROUBLESHOOTING 

 

 

Always visually check the phone for loose or shorted wires, damaged terminals or 
damaged parts. 

 
 

PROBLEM

: NO DIAL TONE   

 
 

POSSIBLE CAUSE

 LINE 

CORD 

 CONNECTOR 
 RJ11C 

CONNECTOR 

 NETWORK 

 

 HANDSET 
 

ATD-11 PRINTED CIRCUIT BOARD 

 
 

PROBLEM

: DIAL TONE IS DISTORTED  

 
 

POSSIBLE CAUSE

 NETWORK 
 HANDSET 
 
 

PROBLEM

: TRANSMITTER DOES NOT TURN ON 

 

 

 
 

POSSIBLE CAUSE

:  

 

 HANDSET 

 

 NETWORK 
 
 

 

 

Summary of Contents for HOB-331-D-M-IVC

Page 1: ...NE and MODEL SSP 311 D M IVC STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH ATD 11 AUTOMATIC DIALER INTERNAL VOLUME CONTROL BACKGROUND NOISE REDUCTION RECEIVER OPERATED SEALED MAGNETIC HOOKSWITCH Servi...

Page 2: ...llowing information is necessary when calling CEECO for assistance MODEL NUMBER SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED Please keep this information on hand when calling CEECO for technical...

Page 3: ...NERAL DESCRIPTION 4 3 0 PROGRAMMING 5 4 0 OPERATION 6 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 6 PROGRAMMING DIAGRAM 7 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 8 7 0 TESTING 10 8 0 TROUBLESHOO...

Page 4: ...activated by hook switch closure The CEECO Model HOB 331 D M IVC is a Weather Resistant Telephone designed for special purpose applications where a durable telephone must be protected from moderate w...

Page 5: ...digits If the number to be programmed is a local call position the J1 mini jumper on the B position bridging the center and right copper pins 3 4 If a 3 digit area code is to be dialed the J3 mini ju...

Page 6: ...hat it bridges the middle and far right copper pins A 3 appears in small white print just right of this position Placing the jumper there will cause the phone to delay 3 to 4 seconds before dialing Th...

Page 7: ...Issue 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 7 PROGRAMMING DIAGRAM...

Page 8: ...sired Mounting hardware is not included The housings are designed to be mounted on a flat vertical surface Mounting holes are provided on the back of the housings In the case of the HOB model a suitab...

Page 9: ...FIDENTIAL This drawing and all information contained therein is confidential and is the exclusive property of CEECO and may not be copied reproduced or disclosed to anyone in any manner whatsoever or...

Page 10: ...a call is placed to the phone and the handset is lifted there is a one and one half to four second delay depending on the position of J2 Section 3 6 the programmed number is dialed and then a normal...

Page 11: ...E DOESN T DIAL PROGRAMMED NUMBER POSSIBLE CAUSE ATD 11 PRINTED CIRCUIT BOARD PROGRAMMING SWITCH MATRIX SET WRONG JUMPER IN WRONG POSITION PROBLEM RINGER DOES NOT OPERATE POSSIBLE CAUSE RINGER NETWORK...

Page 12: ...Steel ENCLOSURE WPP Model Cast Aluminum HOB Model Painted Steel DIMENSIONS WPP Model 12 5 8 High x 9 1 2 Wide x 8 Deep including door HOB Model 11 1 4 High x 7 1 16 Wide x 5 Deep SSP Model 11 1 4 Hig...

Page 13: ...olume Control Button 1 951 007 W Volume Control PCB with wires 1 401 009 Ringer 1 301 009 Network 1 301 592 Magnetic Hook switch 1 301 018 Modular cord 1 331 003 Stainless steel panel for D and X mode...

Page 14: ...hone Network through a registered jack provided by the telephone company in your area This jack is a modular outlet which you can order from your local telephone company 11 3 NOTIFICATION TO THE TELEP...

Page 15: ...he defective unit This information must be inside the shipping container 12 2 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee Florida 34972 863 357 0798 12 3 NON W...

Page 16: ...d to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse act of God or improp...

Reviews: