15

 

11.0  

PARTS 

LIST 

 
 
 

QUANTITY PART NUMBER DESCRIPTION 

 
 

 

1 301-030    INSTRUCTION 

CARD 

KIT 

   

 

 

  1 301-012  OUTER 

COVER 

LOCKING 

SCREW 

   

 

 

  1 301-018  MODULAR 

LINE 

CORD 

   

 

 

  1 SSC-501-F 

(or) STAINLESS 

STEEL 

OUTER 

COVER 

   BLC-501-F 

 BLUE 

POWDER 

COAT 

STEEL 

COVER 

   

 

 

  1 301-039  NUMBER 

WINDOW 

   

 

 

  1 301-040  NUMBER 

CARD 

   

 

 

  1 301-051  BACK 

PLATE 

   

 

 

  1 301-052  RUBBER 

GROMMET 

   

 

 

  1 301-054  MODULAR 

CONNECTOR 

(RJ11C) 

   

 

 

 

 

391-017 

      

KEYPAD CABLE 

   

 

 

 

 

600-SPK 

      

CIRCUIT BOARD WITH MICROPHONE  

 
   

 

14123   

     

SPEAKER 

 
   

 

705-110 

      

CONNECTORIZED KEYPAD  

   

 

 

  1 951-001  MOMENTARY 

PANEL 

SWITCH 

   

 

 

 

 

2          321-016           

SECURITY SCREW  

 
 

ACCESSORIES 

      
      

 

301-064  

 

Security  Tool 

Summary of Contents for BLC-501-F

Page 1: ...1 F OR MODEL BLC 501 F STAINLESS STEEL HANDS FREE CHARGE A CALL TELEPHONE EQUIPPED WITH SPK1 07UNVLr1 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street...

Page 2: ...sistance MODEL NUMBER MODEL SSC 501 F OR BLC 501 F EQUIPPED WITH SPK1 07UNVLr1 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information avail...

Page 3: ...RAMMING CONTINUED 7 PROGRAMMING CONTINUED 8 4 0 SPEED DIAL ALLOWED CALL TABLES 9 PROGRAMMING TABLES CONTINUED 10 5 0 OPERATION 11 6 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 11 7 0 INSTALLATION NOTES AND...

Page 4: ...k Street Okeechobee FL 34972 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 2 0 GENERAL 2 1 The CEECO hands free telephone is a sturdy vandal resistant Stainless Steel Pane...

Page 5: ...s and 70 89 allowed call locations The previous contents of the location are automatically erased when the location code is accessed NOTE Once the pound key has been entered you may get an operator re...

Page 6: ...o incoming calls allowed 1 Incoming calls allowed Digit 3 0 Always 0 for this model Digit 4 0 No Conversation Time Out For Call Button 1 9 Minutes Conversation Time Out Digit 5 0 Always 0 for this mod...

Page 7: ...IGIT 10 250ms WINK LOCATION 30 69 SPEED DIAL TABLE If speed dialing is desired enter the desired numbers in any of these 40 locations The numbers can range from 1 to 11 digits Programming is accomplis...

Page 8: ...wed by the allowed call or call pattern All of these locations may be programmed in a continuous string Be sure to record your entries in the allowed call table for future reference EXAMPLE NOTE The A...

Page 9: ..._ _ _ 56 _ _ _ _ _ _ _ _ _ _ _ 37 _ _ _ _ _ _ _ _ _ _ _ 57 _ _ _ _ _ _ _ _ _ _ _ 38 _ _ _ _ _ _ _ _ _ _ _ 58 _ _ _ _ _ _ _ _ _ _ _ 39 _ _ _ _ _ _ _ _ _ _ _ 59 _ _ _ _ _ _ _ _ _ _ _ 40 _ _ _ _ _ _ _ _...

Page 10: ..._ _ _ 84 _ _ _ _ _ _ _ _ _ _ _ 75 _ _ _ _ _ _ _ _ _ _ _ 85 _ _ _ _ _ _ _ _ _ _ _ 76 _ _ _ _ _ _ _ _ _ _ _ 86 _ _ _ _ _ _ _ _ _ _ _ 77 _ _ _ _ _ _ _ _ _ _ _ 87 _ _ _ _ _ _ _ _ _ _ _ 78 _ _ _ _ _ _ _ _...

Page 11: ...o programmed NOTE In some cases a local PBX does not automatically send a wink back as a Central Office would Some of these PBXs can be programmed to do so It would be necessary to contact the manufac...

Page 12: ...as it contains required over voltage protection 7 5 The use of a gas tube or carbon station protector is recommended The station ground should not exceed 50 ohms 7 6 Plug the modular line cord from t...

Page 13: ...n Connect the phone to a working phone line Press the black CALL button Reaction Dial tone Action Dial a number Reaction The called party answers A normal speakerphone conversation is allowed Action F...

Page 14: ...A minimum 80mA Maximum IMPEDANCE 600 ohms SIGNALING DTMF OUTPUT 2 0dbm to 0dbm ENVIRONMENTAL Temperature 0oC to 50oC Humidity 20 90 TELEPHONE PANEL Stainless Steel 14ga DIMENSIONS 7 1 2 Wide x 21 High...

Page 15: ...ORD 1 SSC 501 F or STAINLESS STEEL OUTER COVER BLC 501 F BLUE POWDER COAT STEEL COVER 1 301 039 NUMBER WINDOW 1 301 040 NUMBER CARD 1 301 051 BACK PLATE 1 301 052 RUBBER GROMMET 1 301 054 MODULAR CONN...

Page 16: ...one Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 12 3 NOTIFICATION TO THE TELEPH...

Page 17: ...to the defective unit This information must be inside the shipping container 13 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco...

Page 18: ...d to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse act of God or improp...

Page 19: ...hen programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON position BE...

Page 20: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 20...

Reviews: