background image

© CEDES | V 1.3

 

3

TOF/Taxi

English

2. Safety information

IMPORTANT!

READ BEFORE INSTALLATION!

The  TOF/Taxi  was  developed  and  manufactured 

using  state-of-the-art  systems  and  technologies. 

However, injury and damage to the sensor can still 

occur.

To ensure safe conditions:

 

Read all enclosed instructions and information.

 

Follow the instructions given in this manual 

carefully. 

 

Observe all warnings included in the  

documentation and attached to the sensor.

 

Do not use the sensor if it is damaged in any way.

 

Keep the instruction manual on site.

The TOF/Taxi should only be installed by authorized 

and fully trained personnel! The installer or system 

integrator is fully responsible for the safe integration 

of  the  sensor.  It  is  the  sole  responsibility  of  the 

planner  and/or  installer  and/or  buyer  to  ensure 

that this product is used according to all applicable 

standards,  laws  and  regulations  in  order  to  ensure 

safe operation of the whole application. 

Any alterations to the device by the buyer, installer 

or  user  may  result  in  unsafe  operating  conditions. 

CEDES is not responsible for any liability or warranty 

claim that results from such manipulation.

Failure  to  follow  instructions  given  in  this  manual  

and/or  other  documents  related  to  the  TOF/Taxi 

may cause customer complaints, serious call backs, 

damage, injury or death. 

2.1  Non-intended use

The TOF/Taxi 

must not

 be used for:

•  Equipment in explosive atmospheres

•  Equipment in radioactive environments

Use  only  specific  and  approved  safety  devices  for 

such applications, otherwise serious injury or death 

or damage to property may occur!

3. Symbols, safety messages 

Symbol

Meaning

 

 

Single instruction or measures in 

no particular order

1. 
2. 
3. 

 

Sequenced instructions

List, in no order of importance

Reference to a chapter, illustration 

or table within this document

Important:

Important  information  for  the  

correct use of the sensor

3.1  Safety message categories

Warning of serious health risks

WARNING

Serious health risks

Highlights critical information for the safe use 

of the sensor. 

Disregarding these warnings 

can result in serious injury or death.

 

Follow  the  measures  highlighted  by  the 

triangle-shaped arrows

 

Consult the safety information in Chapter 

2 of this manual

Caution of possible health risks

CAUTION

Possible health risks

Highlights critical information for the safe use 

of the sensor. 

Disregarding these warnings 

can result in injury.

 

Follow  the  measures  highlighted  by  the 

triangle-shaped arrows

 

Consult the safety information in Chapter 

2 of this manual

Notice of damage risk

NOTICE

Risk of damage

Disregarding  these  notices  can  lead  to 

damage  to  the  sensor,  the  door  controller  

and/or other devices.

 

Follow  the  measures  highlighted  by  the 

triangle-shaped arrows

Summary of Contents for TOF/TaxI

Page 1: ...Seiten 19 36 CEDES AG is certified according to ISO 9001 2008 CEDES AG ist zertifiziert nach ISO 9001 2008 Installation and Operation Manual Montage und Betriebsanleitung 109 949 120822 V 1 3 TOF Tax...

Page 2: ...ers 2 2 Safety information 3 2 1 Non intended use 3 3 Symbols safety messages 3 3 1 Safety message categories 3 4 Introduction 4 4 1 Features of the TOF Taxi 4 4 2 Type description 4 5 Overview 5 5 1...

Page 3: ...r complaints serious call backs damage injury or death 2 1 Non intended use The TOF Taxi must not be used for Equipment in explosive atmospheres Equipment in radioactive environments Use only specific...

Page 4: ...area i e the wall can be ignored by the sensor Door handles can also be ignored by the sensor Figure 1 A typical TOF Taxi application 4 1 Features of the TOF Taxi Time of Flight principle TOF Provides...

Page 5: ...ed on the hinge edges of a double swing door synchronization is necessary Chapter 11 CAUTION Damage to the eye Although the TOF Taxi does not emit dangerous amounts of infrared light long exposure to...

Page 6: ...cation installation and settings The TOF Taxi can be mounted on both the leading edge Figure 3 and the hinge edge Figure 4 of a door Dimensions vary according to mounting height All measurements in mm...

Page 7: ...door is irrelevant to the setting of DIP switch 1 Table 1 DIP switch 1 settings DIP switch 1 position Mounting position ON Mounting on the right OFF Mounting on the left 6 2 DIP switch 2 Number of ac...

Page 8: ...e from triggering the TOF Taxi the area containing the door handle can be blanked by setting DIP switch 4 to ON This reduces the detection area length of Row 1 by approximately 1 m 40 in putting it we...

Page 9: ...his example the value is 3 4 Set Pot 2 using a small screwdriver Detection area width w in Detection area length l in 40 12 14 16 18 20 22 24 26 28 50 15 17 20 22 25 27 30 32 35 60 18 21 24 27 30 33 3...

Page 10: ...cable must be guided along the surface of the door 3 Fix the mounting plate using the mounting screws included with the sensor kit Figure 15 Make sure that the raised hole in the center of the mounti...

Page 11: ...e for further information Example A PNP DO output is LOW when an object or person is detected HIGH if the detection area is free Chapter 12 NOTICE Possible damage to the output PNP outputs need a pull...

Page 12: ...onse Chapter 12 10 LED functions LED status Meaning green no object detected detection area clear red object detected detection area needs to be adjusted Table 9 LED functions 11 Synchronization If se...

Page 13: ...opening test before closing test before closing test before opening Door closing signal input Door open signal input Door closing signal input Door controller left door wing right door wing green 1 4...

Page 14: ...s obstructed but green LED is on Make sure the detection area length and width are set correctly Detection area is free but red LED is on Make sure the detection area length and width are set correctl...

Page 15: ...NOTICE Damage to the optical window Never use any solvents cleaners or mechanically abrasive towels or high pressure water to clean the sensor 15 Uninstalling TOF Taxi Using a screwdriver carefully pr...

Page 16: ...VDC 150 mA peak max 400 mA Output PNP or NPN Max output load 50 mA 100 nF Response time typical 150 ms Output status indication LED Red object detected Green no object Connection cable and electrical...

Page 17: ...important dimensions of the TOF Taxi 60 0 1 15 5 5 42 5 45 10 5 4 5 5 139 69 59 133 4 TOF Taxi sensor 2 36 0 1 0 61 5 1 67 1 77 0 41 0 18 0 2 5 47 2 71 2 32 5 24 0 16 TOF Taxi sensor Metric measureme...

Page 18: ......

Page 19: ...19 CEDES AG ist zertifiziert nach ISO 9001 2008 Montage und Betriebsanleitung TOF Taxi EN 13849 1 RoHS D0AS0001...

Page 20: ...timmungsgem sse Verwendung 21 3 Verwendete Symbole und Warnhinweise 21 3 1 Warnhinweiskategorien 21 4 Einleitung 22 4 1 Eigenschaften von TOF Taxi 22 4 2 Typendefinition 22 5 bersicht 23 5 1 Lieferumf...

Page 21: ...r Tod zur Folge haben 2 1 Nicht bestimmungsgem sse Verwendung TOF Taxi darf nicht verwendet werden f r Anlagen in explosiven Atmosph ren Anlagen in radioaktiven Atmosph ren F r solche Anwendungen d rf...

Page 22: ...en T rklinken erkannt und ausgeblendet Abb 1 Typische Anwendung von TOF Taxi 4 1 Eigenschaften von TOF Taxi Time of Flight Prinzip TOF Blendet W nde und T rklinken automatisch aus und bleibt dabei sic...

Page 23: ...Werden mehrere TOF Taxi ber den Nebenschliesskanten einer doppelfl gligen Schwingt r montiert ben tigen sie Synchronisation Kapitel 11 VORSICHT Augenverletzungen durch Infrarotlicht Obwohl TOF Taxi ke...

Page 24: ...des Sensors h ngt von der Anwendung und den gew hlten Einstellungen ab TOF Taxi kann ber der Hauptschliesskante Abb 3 oder ber der Nebenschliesskante Abb 4 montiert werden Die Abmessungen des berwachu...

Page 25: ...t f r die Einstellungen an DIP Schalter 1 keine Rolle Tabelle 1 Einstellungen DIP Schalter 1 Position DIP Schalter 1 Montageposition ON Rechte Montageposition OFF Linke Montageposition 6 2 DIP Schalte...

Page 26: ...zur Wand mindestens 0 15 m betragen Tabelle 3 Einstellungen DIP Schalter 3 Position DIP Schalter 3 Wandausblendung ON Aktiviert OFF Deaktiviert 6 4 DIP Schalter 4 T rklinkenausblendung Damit die T rk...

Page 27: ...eingestellt worden Nun soll die berwachungsfeldsbreite b auf 1 5 m eingestellt werden 1 Zeile mit der passenden berwachungsfeldh he h suchen im Beispiel 2 5 m 2 In dieser Zeile die ben tigte berwachun...

Page 28: ...hrt werden Andernfalls muss das Kabel der T rblattoberfl che entlang gef hrt werden 3 Montageplatte mit den mitgelieferten Befestigungsschrauben am T rblatt fixieren flache Seite gegen aussen Abb 15 A...

Page 29: ...Ein PNP DO Ausgang ist LOW solange ein Objekt oder eine Person erkannt wird Wird das berwachungsfeld frei schaltet der PNP DO Ausgang auf HIGH Kapitel 12 HINWEIS M gliche Sch den am Ausgang Der PNP A...

Page 30: ...v schalten Kapitel 8 2 2 Reaktion des Signalausgangs berpr fen Kapitel 12 10 LED Funktionen LED Zustand Bedeutung leuchtet gr n kein Objekt erkannt berwachungsfeld frei leuchtet rot Objekt erkannt ber...

Page 31: ...gnaleingang T r ffnung Signaleingang T rschliessung T rsteuerung T rsteuerung vor dem Schliessen testen vor dem ffnen testen vor dem ffnen testen vor dem Schliessen testen linker T rfl gel rechter T r...

Page 32: ...achungsfeldh he und breite korrekt eingestellt Blockiert die T rklinke das berwachungsfeld Erkennt TOF Taxi f lschlicherweise den Boden Falls sich die T r gegen eine Wand ffnet Ist die Wandausblendung...

Page 33: ...F Taxi nie mit L sungs oder Reinigungsmitteln abrasiven Reinigungst chern oder Hochdruckwasser reinigen Das optische Fenster kann dabei besch digt werden 15 Demontage TOF Taxi Leichter Druck z B mit e...

Page 34: ...PNP oder NPN Ausgangslast Max 50 mA 100 nF Ansprechzeit typisch 150 ms Ausgang Statusanzeige LED Rot Objekt erkannt Gr n kein Objekt erkannt Anschlusskabel und elektrische Anschl sse Material PVC sch...

Page 35: ...i English CEDES V 1 3 35 TOF Taxi Deutsch 18 Abmessungen Die wichtigsten Abmessungen f r TOF Taxi Abb 25 Abmessungen TOF Taxi alle Masse in mm 60 0 1 15 5 5 42 5 45 10 5 4 5 5 139 69 59 133 4 TOF Taxi...

Page 36: ...112 1 3 4 5 6 6 7 6 6 6 899 8 4 6 2 2 4 0 ABC D3AE899C A9993 38E899F A9993 3BE899G H I H J 1 7 5 5 I3A8310399C 0 0 J 5 KE 2940999A 2 L L 4 5 6 56 5K 2 M L N J 2 O N J 2 2 N 2 J 5 N 2 J 2 K P 2 J A9DD...

Page 37: ...TOF Taxi English CEDES V 1 3 37 TOF Taxi...

Page 38: ...TOF Taxi 38 CEDES V 1 3 TOF Taxi...

Page 39: ...TOF Taxi English CEDES V 1 3 39 TOF Taxi...

Page 40: ...CEDES AG Science Park CH 7302 Landquart Phone 41 81 307 2323 Fax 41 81 307 2325 info cedes com www cedes com...

Reviews: