Pot 1: Detection area length
Pot 1 is located directly to the right of
the DIP switches. It sets the detection
area length (l) between 1 m (40 in)
and 3 m (120 in).
Important:
The detection area length
must be set about 0.2 m (8 in) above
floor level as the floor would otherwise
interfere with the sensor’s detection
ability.
Adjust Pot 1 according to
Table 5 / Table 6.
Pot 2: Detection area width
Pot 2 sets the detection area width (w)
in relation to the detection area length.
The width can be adjusted between 0.3
and 0.7 × the detection area length.
Adjust Pot 2 according to Table 7 /
Table 8.
Example (row/column highlighted
in gray)
: For a door 2.7 m (108 in) high
and 1.5 m (59 in) wide, the detection
area length (l) has already been set
to 2.5 m (100 in). The detection area
width (w) should now be set to 1.5 m
(59 in). In order to do this, take the
following steps:
1.
Look up the corresponding
detection area
length
row in
Table 7 / Table 8
(i.e. 2.5 m / 100 in).
2.
Move along this row to the desired
detection area
width
(i.e. 1.5 m /
59 in).
3.
Directly below this figure you will
find the required
Pot 2 setting
, in
this example the value is 3.
4.
Set Pot 2 using a small
screwdriver
Detection area width w [in]
Detection area length l [in]
40
12
14
16
18
20
22
24
26
28
50
15
17
20
22
25
27
30
32
35
60
18
21
24
27
30
33
35
39
41
70
21
24
28
31
35
38
41
45
48
80
24
27
32
35
39
43
47
51
55
90
27
31
35
40
45
49
53
58
62
100
30
35
39
45
49
54
59
64
69
110
33
38
43
49
54
59
65
71
76
120
35
41
47
53
59
65
71
77
83
0
0.5
1
1.5
2
2.5
3
3.5
4
Pot 2 setting
Table 8:
Pot 2 / Detection area width
in inches
Table 5:
Pot 1 / Detection area length
in m
Detection area
length l [m]
1 1.25 1.5 1.75 2 2.25 2.5 2.75 3
Pot 1 setting
0
0.5
1
1.5
2
2.5
3
3.5
4
Table 6:
Pot 1 / Detection area length
in inches
Detection area
length l [in]
40
50
60
70
80
90 100 110 120
Pot 1 setting
0
0.5
1
1.5
2
2.5
3
3.5
4
Detection area width w [m]
Detection area length l [m]
1.0
0.3
0.35
0.4
0.45
0.5
0.55
0.6
0.65
0.7
1.25 0.38 0.44
0.5
0.56 0.63 0.69 0.75 0.81 0.88
1.50 0.45 0.53 0.60 0.68 0.75 0.83
0.9
0.98 1.05
1.75 0.53 0.61
0.7
0.79 0.88 0.96 1.05 1.14 1.23
2
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
2.25 0.68 0.79
0.9
1.01 1.13 1.24 1.35 1.46 1.58
2.5
0.75 0.88
1
1.13 1.25 1.38
1.5
1.63 1.75
2.75 0.83 0.96
1.1
1.24 1.38 1.51 1.65 1.79 1.93
3.0
0.9
1.05
1.2
1.35
1.5
1.65
1.8
1.95
2.1
0
0.5
1
1.5
2
2.5
3
3.5
4
Pot 2 setting
Table 7:
Pot 2 / Detection area width
in m