page 3
page 10
TORQUE MEASUREMENT
TORQUE MEASUREMENT
SPECIFICATIONS
ON/OFF
Press to turn on or off (click once, do not hold). After 10
minutes of non-use the unit shuts off.
MODE
Select
Real Time
,
PP
(Peak),
PD
(Peak Down),
C
(Continuous Output mode)
CLEAR
Reset display to zero and send data to memory
LCD display
Displays torque value, battery icon, mode & units.
GO/NG Indicator
Green for values between LO and HI setpoints,
flashing red for values above HI, solid green for data output
DOWN
Change values or numeric places
UP
Change values or options
PRG
Enter programming mode or enter values
MEM
Display memory locations and data
STAT
Display statistics; number of records, Max, Min, and Ave
DC IN
USB PORT
RATCHET
RESET
CHARGE LIGHT
BATTERY ICON
MODE
STATS
UNITS
Ratchet Operation
CW, CCW and fixed positions
USB Port
Send data to computer via USB cable
Charge light
lights when charging, off when complete.
DC IN
AC charger/adapter receptacle
RESET
System reset button
1
2
3
4
5
6
7
8
9
10
6
7
8
9
10
2
1
3
4
5
Measuring range
2.0~560.0 ozf-in 0.20~35.00 lbf-in 0.20~40.00 kgf-cm
2.0~400.0 N-cm 0.2~4.000 N-m
Accuracy
± 0.5% F.S., ±1 LSD
Display
4 digit LCD
Operation
CW, CCW and fixed position
Measuring modes
PP: Peak Mode displays PEAK torque value that will not change until a
higher value is measured.
PD: Peak Down Mode Captures first peak down value above the PDLO
Real Time: Displays transient torque values
C: Real-time Output 180 data per second
GO/NO GO testing
Programmable High and Low setpoints with both audible beep and
Green/Red LED indicator
Statistics
Number of data, maximum, minimum and average
Data transfer
ASCII, 19200 bps, USB miniB cable
Data memory
800 data
Batch Counter
1-99 (CW only)
Power supply
Ni-Cad rechargeable batteries 1.2V×4cells 600mAh
Auto power save
Automatic switch off after 10 minutes of non-use
Charging time
From empty - less than 5hours
Working time
12 hours continuous use
Bit size
6.35mm
Weight
430g
Accessories
AC/DC Adapter/Charger, 100~230VAC, 2 Phillips bits, NIST certificate