TORQUE MEASUREMENT

TORQUE MEASUREMENT

SPECIFICATIONS

ON/OFF 

Press to turn on or off (click once, do not hold).  After 10

minutes of non-use the unit shuts off.

MODE 

Select

Real Time

PP

(Peak), 

PD

(Peak Down),

C

(Continuous Output mode)

CLEAR 

Reset display to zero and send data to memory

LCD display

Displays torque value, battery icon, mode & units.

GO/NG Indicator 

Green for values between LO and HI setpoints,

flashing red for values above HI, solid green for data output

DOWN 

Change values or numeric places

UP 

Change values or options

PRG 

Enter programming mode or enter values

MEM 

Display memory locations and data

STAT 

Display statistics; number of records, Max, Min, and Ave

DC IN

USB PORT

RATCHET

RESET

CHARGE LIGHT

BATTERY ICON

MODE

STATS

UNITS 

Ratchet Operation

CW, CCW and fixed positions

USB Port

Send data to computer via USB cable

Charge light

lights when charging, off when complete.

DC IN

AC charger/adapter receptacle

RESET

System reset button

1

2

3

4

5

6

7

8

9

10

6

7

8

9

10

2

1

3

4

5

Measuring range

2.0~560.0 ozf-in   0.20~35.00 lbf-in   0.20~40.00 kgf-cm   
2.0~400.0 N-cm   0.2~4.000 N-m

Accuracy

± 0.5% F.S., ±1 LSD 

Display

4 digit LCD

Operation

CW, CCW and fixed position

Measuring modes

PP: Peak Mode displays PEAK torque value that will not change until a 
higher value is measured.
PD: Peak Down Mode Captures first peak down value above the PDLO
Real Time: Displays transient torque values
C: Real-time Output 180 data per second

GO/NO GO testing

Programmable High and Low setpoints with both audible beep and 
Green/Red LED indicator

Statistics

Number of data, maximum, minimum and average

Data transfer

ASCII, 19200 bps, USB miniB cable

Data memory

800 data

Batch Counter

1-99 (CW only)

Power supply

Ni-Cad rechargeable batteries 1.2V×4cells 600mAh

Auto power save

Automatic switch off after 10 minutes of non-use

Charging time

From empty - less than 5hours

Working time

12 hours continuous use

Bit size

6.35mm

Weight 

430g

Accessories

AC/DC Adapter/Charger, 100~230VAC, 2 Phillips bits, NIST certificate

Summary of Contents for DID-4

Page 1: ...t prepaid The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY and we hereby disclaim all other warranties express statutory or implied applicable to the products and or software including but not limited to all implied warranties of merchantability fitness non infringement results accuracy security and freedom from computer virus In no event shall Imada Inc and or its affiliated com...

Page 2: ... 100ºF Do not apply torque exceeding the rated capacity 35 lbf in regardless of whether the unit is On or Off Avoid shock load When charging the battery be sure to use the provided AC adapter charger exclusively Do not use lacquer thinner or any solvent to clean the unit Do not disassemble or modify the unit Digital Torque Tester Screwdriver Model DID 4 List of Equipment DIgital Torque Tester Scre...

Page 3: ...AC charger adapter receptacle RESET System reset button 1 2 3 4 5 6 7 8 9 10 6 7 8 9 10 2 1 3 4 5 Measuring range 2 0 560 0 ozf in 0 20 35 00 lbf in 0 20 40 00 kgf cm 2 0 400 0 N cm 0 2 4 000 N m Accuracy 0 5 F S 1 LSD Display 4 digit LCD Operation CW CCW and fixed position Measuring modes PP Peak Mode displays PEAK torque value that will not change until a higher value is measured PD Peak Down Mo...

Page 4: ...t PP appears on the display PD Mode First Peak capture first peak value peak data output PD appears on the display C Mode Continuous RS 232 output Display and output torque transients 180 data sec C appears on the display 2 Insert Phillips tip into the screwdriver 3 To select ratchet operation turn the ratchet one click clockwise or counter clockwise from the center position To disable ratcheting ...

Page 5: ... place and press the UP to select values then press PRG to enter CLO sets the start and stop trigger points for Continuous data output When torque reaches the CLO value the tester starts to output data and stops if torque falls below the value Note the display does not show any value below the CLO minimum 5 Auto Zero Reset AC After Continuous Data Output Minimum is entered AC is dis played then th...

Page 6: ...on and value Clearing Data from Memory Single clear Press MEM then press UP or DOWN to move to a memory location When the desired memory value is displayed press CLR CLR is displayed Press CLR again to clear the data and is displayed to confirm deletion All clear Press CLR and hold until the display shows ALL then press CLR again and is displayed to confirm deletion Downloading Memory Data 1 Press...