www.usaprocom.com
200032-01A
20
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
to the
OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
to the
PILOT position.
MANUAL LIGHTING PROCEDURE
1. Remove front panel.
2. Follow steps 2 through 5 under
Lighting
Instructions
, page 19.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Follow step 8 under
Lighting Instructions
, above.
5. Replace front panel.
Figure 24 - Pilot Assembly
Pilot Air
Inlet Hole
Natural
Gas
Burner
Propane/LP
Gas Burner
Ignitor
Electrode
Thermocouple
Pilot Air Inlet Hole
OPERATION
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this model
differs from standard thermostats. Standard
thermostats simply turn the burner on and off.
The thermostat used on this heater senses the
room temperature. At times the room may ex-
ceed the set temperature. If so, the burner will
shut off. The burner will cycle back on when
room temperature drops below the set tem-
perature. The control knob can be set to any
comfort level between HIGH (5) and LOW (1).
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the front of burner. The pilot can be
seen through the grill. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 25 though 27.
Also contact a qualified service technician
or gas supplier for repairs. Until repairs
are made, light pilot with match. To light
pilot with match, see Manual Lighting
Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. If control knob does
not pop up when released, contact a quali-
fied service technician or gas supplier for
repairs.
Note: If pilot goes out, repeat steps 2
through 6. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between 1 and 5.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot
burner ignites. If input gas type
is LP, make sure LP pilot burner
ignites.